Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim

The objective of this project is to study the Impact Performance and Fracture Toughness using falling weight Impact Apparatus to PMC and PMC/FRP composite. In general, the project involves the following activities: i. Literature Review of the Impact Systems ii. Design and Fabrication of Falling W...

Full description

Bibliographic Details
Main Author: Jusoh @ Ibrahim, Mohammad Helmi
Format: Thesis
Language:English
Published: 2004
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/21151/
http://ir.uitm.edu.my/id/eprint/21151/1/TD_MOHAMMAD%20HELMI%20JUSOH%20%40%20IBRAHIM%20EM%2004_5.pdf
id uitm-21151
recordtype eprints
spelling uitm-211512018-10-17T03:33:53Z http://ir.uitm.edu.my/id/eprint/21151/ Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim Jusoh @ Ibrahim, Mohammad Helmi Composite materials. The objective of this project is to study the Impact Performance and Fracture Toughness using falling weight Impact Apparatus to PMC and PMC/FRP composite. In general, the project involves the following activities: i. Literature Review of the Impact Systems ii. Design and Fabrication of Falling Weight Impact System iii. Preliminary investigation of Impact Strength of PMC and PMC/FRP The test rig consists of Long Plates (Stand,) support plates (clamped the guide tube) base plates, hollow pipe (guide tube), Plunger (Loading), some part of instrument test and three point Bend tester. All the materials are attached together followed the design specification. The plunger Drop in the hollow pipe at the certain height are released to fly out when falling, at the same time as the nose of the drop-weight is about to make contact with the specimen underneath. Instrument part is setting automatically, loading (plunger) is Drop to impact the Specimen and data will set up. The signals on vibrating from Load Cell send to the charge amplifier and Oscilloscope. The preliminary data are getting based on the harmonic Oscillations. Some result of test to be conducted. The data are shows that the harmonics based on the vibrating on the impact test. The graph will be plot that the Loading versus time. This specimen can be tested based on the Falling Weight Impact Apparatus, Three Point Bend Method and some other instrument. The Impact Energy can be calculated based on the mass of loading, height and load at graph. All the experimental, fabricated work and the tests can be carried out in the faculty of mechanical’s Laboratories. 2004 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/21151/1/TD_MOHAMMAD%20HELMI%20JUSOH%20%40%20IBRAHIM%20EM%2004_5.pdf Jusoh @ Ibrahim, Mohammad Helmi (2004) Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim. Degree thesis, Universiti Teknologi MARA.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Composite materials.
spellingShingle Composite materials.
Jusoh @ Ibrahim, Mohammad Helmi
Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim
description The objective of this project is to study the Impact Performance and Fracture Toughness using falling weight Impact Apparatus to PMC and PMC/FRP composite. In general, the project involves the following activities: i. Literature Review of the Impact Systems ii. Design and Fabrication of Falling Weight Impact System iii. Preliminary investigation of Impact Strength of PMC and PMC/FRP The test rig consists of Long Plates (Stand,) support plates (clamped the guide tube) base plates, hollow pipe (guide tube), Plunger (Loading), some part of instrument test and three point Bend tester. All the materials are attached together followed the design specification. The plunger Drop in the hollow pipe at the certain height are released to fly out when falling, at the same time as the nose of the drop-weight is about to make contact with the specimen underneath. Instrument part is setting automatically, loading (plunger) is Drop to impact the Specimen and data will set up. The signals on vibrating from Load Cell send to the charge amplifier and Oscilloscope. The preliminary data are getting based on the harmonic Oscillations. Some result of test to be conducted. The data are shows that the harmonics based on the vibrating on the impact test. The graph will be plot that the Loading versus time. This specimen can be tested based on the Falling Weight Impact Apparatus, Three Point Bend Method and some other instrument. The Impact Energy can be calculated based on the mass of loading, height and load at graph. All the experimental, fabricated work and the tests can be carried out in the faculty of mechanical’s Laboratories.
format Thesis
author Jusoh @ Ibrahim, Mohammad Helmi
author_facet Jusoh @ Ibrahim, Mohammad Helmi
author_sort Jusoh @ Ibrahim, Mohammad Helmi
title Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim
title_short Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim
title_full Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim
title_fullStr Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim
title_full_unstemmed Impact performance and fracture toughness of PMC and PMC/FRP composite / Mohammad Helmi Jusoh @ Ibrahim
title_sort impact performance and fracture toughness of pmc and pmc/frp composite / mohammad helmi jusoh @ ibrahim
publishDate 2004
url http://ir.uitm.edu.my/id/eprint/21151/
http://ir.uitm.edu.my/id/eprint/21151/1/TD_MOHAMMAD%20HELMI%20JUSOH%20%40%20IBRAHIM%20EM%2004_5.pdf
first_indexed 2023-09-18T23:05:57Z
last_indexed 2023-09-18T23:05:57Z
_version_ 1777418484012023808