Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman

The experimental study on the Behaviour of Profiled Steel Sheet Dry Board System (PSSDB) with Door Opening as load bearing wall were carried out. PSSDB is formed by Profiled Steel Sheet (BONDEK II) connected to two the dry boards (CEMBOARD) using self-tapping screws. The study of PSSDB system involv...

Full description

Bibliographic Details
Main Author: Arman, Zaharil Nikman @ Muhammad
Format: Student Project
Language:English
Published: Faculty of Civil Engineering 2002
Online Access:http://ir.uitm.edu.my/id/eprint/18133/
http://ir.uitm.edu.my/id/eprint/18133/2/PPb_ZAHARIL%20NIKMAN%20MUHAMMAD%20ARMAN%20EC%2002_5.pdf
id uitm-18133
recordtype eprints
spelling uitm-181332019-02-18T01:55:39Z http://ir.uitm.edu.my/id/eprint/18133/ Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman Arman, Zaharil Nikman @ Muhammad The experimental study on the Behaviour of Profiled Steel Sheet Dry Board System (PSSDB) with Door Opening as load bearing wall were carried out. PSSDB is formed by Profiled Steel Sheet (BONDEK II) connected to two the dry boards (CEMBOARD) using self-tapping screws. The study of PSSDB system involved doubleskin composite walling panel. The experiment carried out was to determine the behaviour of this system under axial load. There were four samples tested with and without overlapping of profiled steel sheet. The size of sample was 600mm width and 1000mm height. The size of door opening was 186mm width and 680mm height. The parameters measured and determined were deflections, overall buckling, crushing on panel, Young’s Modulus (E) and ultimate load capacity. From the experiment, load displacement curve and stressstrain relationship were identified. The average ultimate load capacity for the overlap sample was 214kN and the ultimate load capacity for the non-overlap was 138kN. Faculty of Civil Engineering 2002 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18133/2/PPb_ZAHARIL%20NIKMAN%20MUHAMMAD%20ARMAN%20EC%2002_5.pdf Arman, Zaharil Nikman @ Muhammad (2002) Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
description The experimental study on the Behaviour of Profiled Steel Sheet Dry Board System (PSSDB) with Door Opening as load bearing wall were carried out. PSSDB is formed by Profiled Steel Sheet (BONDEK II) connected to two the dry boards (CEMBOARD) using self-tapping screws. The study of PSSDB system involved doubleskin composite walling panel. The experiment carried out was to determine the behaviour of this system under axial load. There were four samples tested with and without overlapping of profiled steel sheet. The size of sample was 600mm width and 1000mm height. The size of door opening was 186mm width and 680mm height. The parameters measured and determined were deflections, overall buckling, crushing on panel, Young’s Modulus (E) and ultimate load capacity. From the experiment, load displacement curve and stressstrain relationship were identified. The average ultimate load capacity for the overlap sample was 214kN and the ultimate load capacity for the non-overlap was 138kN.
format Student Project
author Arman, Zaharil Nikman @ Muhammad
spellingShingle Arman, Zaharil Nikman @ Muhammad
Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman
author_facet Arman, Zaharil Nikman @ Muhammad
author_sort Arman, Zaharil Nikman @ Muhammad
title Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman
title_short Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman
title_full Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman
title_fullStr Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman
title_full_unstemmed Behaviour of profiled steel sheet dry board system as walling unit with door opening / Zaharil Nikman @ Muhammad Arman
title_sort behaviour of profiled steel sheet dry board system as walling unit with door opening / zaharil nikman @ muhammad arman
publisher Faculty of Civil Engineering
publishDate 2002
url http://ir.uitm.edu.my/id/eprint/18133/
http://ir.uitm.edu.my/id/eprint/18133/2/PPb_ZAHARIL%20NIKMAN%20MUHAMMAD%20ARMAN%20EC%2002_5.pdf
first_indexed 2023-09-18T22:59:50Z
last_indexed 2023-09-18T22:59:50Z
_version_ 1777418099030491136