A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad

In modern day, people mostly adult living in indoor compare to outdoor due to working purposed. A result of a research from cdc.gov,2014 indicate that people spent about 90% of their time indoor. The research also indicate that the air inside a building is more polluted compare to outdoor air. The p...

Full description

Bibliographic Details
Main Author: Muhammad, Ahmad Izzat Nazmi
Format: Student Project
Language:English
Published: Faculty of Architecture, Planning and Surveying 2014
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/15835/
http://ir.uitm.edu.my/id/eprint/15835/1/PPb_AHMAD%20IZZAT%20NAZMI%20MUHAMMAD%20AP%2014_5.pdf
id uitm-15835
recordtype eprints
spelling uitm-158352016-12-17T06:04:38Z http://ir.uitm.edu.my/id/eprint/15835/ A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad Muhammad, Ahmad Izzat Nazmi Estimates. Measurements. Quantities and cost Building control systems Heating and ventilation. Air conditioning In modern day, people mostly adult living in indoor compare to outdoor due to working purposed. A result of a research from cdc.gov,2014 indicate that people spent about 90% of their time indoor. The research also indicate that the air inside a building is more polluted compare to outdoor air. The problems arise when these indoor air quality affect the health of the occupants health. Therefore, three office building was studied in this research. In this studies, only one factor of indoor air quality is being focused which is dust in the air. By using appropriate equipment which is Dust Trak Meter, the air in the selected office room of case study building will be tested. Other than that, an interview to the occupant of the room will be conducted to get more information about the IAQ in the selected room. Finally, the data collected will be analyzed. The finding from the study shows dust concentration in each case study room are appropriate condition whereby room with renovation works represent the highest dust concentration. Follow up by the old office room and lastly the new office room that has lowest dust concentration. Thus, proper conclusion and recommendation will be provided to overcome the indoor air quality problems in the future. Faculty of Architecture, Planning and Surveying 2014 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/15835/1/PPb_AHMAD%20IZZAT%20NAZMI%20MUHAMMAD%20AP%2014_5.pdf Muhammad, Ahmad Izzat Nazmi (2014) A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Estimates. Measurements. Quantities and cost
Building control systems
Heating and ventilation. Air conditioning
spellingShingle Estimates. Measurements. Quantities and cost
Building control systems
Heating and ventilation. Air conditioning
Muhammad, Ahmad Izzat Nazmi
A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad
description In modern day, people mostly adult living in indoor compare to outdoor due to working purposed. A result of a research from cdc.gov,2014 indicate that people spent about 90% of their time indoor. The research also indicate that the air inside a building is more polluted compare to outdoor air. The problems arise when these indoor air quality affect the health of the occupants health. Therefore, three office building was studied in this research. In this studies, only one factor of indoor air quality is being focused which is dust in the air. By using appropriate equipment which is Dust Trak Meter, the air in the selected office room of case study building will be tested. Other than that, an interview to the occupant of the room will be conducted to get more information about the IAQ in the selected room. Finally, the data collected will be analyzed. The finding from the study shows dust concentration in each case study room are appropriate condition whereby room with renovation works represent the highest dust concentration. Follow up by the old office room and lastly the new office room that has lowest dust concentration. Thus, proper conclusion and recommendation will be provided to overcome the indoor air quality problems in the future.
format Student Project
author Muhammad, Ahmad Izzat Nazmi
author_facet Muhammad, Ahmad Izzat Nazmi
author_sort Muhammad, Ahmad Izzat Nazmi
title A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad
title_short A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad
title_full A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad
title_fullStr A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad
title_full_unstemmed A study on indoor air quality of office building / Ahmad Izzat Nazmi Muhammad
title_sort study on indoor air quality of office building / ahmad izzat nazmi muhammad
publisher Faculty of Architecture, Planning and Surveying
publishDate 2014
url http://ir.uitm.edu.my/id/eprint/15835/
http://ir.uitm.edu.my/id/eprint/15835/1/PPb_AHMAD%20IZZAT%20NAZMI%20MUHAMMAD%20AP%2014_5.pdf
first_indexed 2023-09-18T22:54:45Z
last_indexed 2023-09-18T22:54:45Z
_version_ 1777417779249414144