Optimum spacing between grooved tubes: an experimental study

An experimental study on the optimum spacing between grooved tubes is reported in this paper. Two grooved tubes having a pitch of 10 mm and 15 mm and a plain tube were considered for the heat transfer analysis. The spacing between two tubes with the same pitch was varied from 10 mm to 35 mm with a s...

Full description

Bibliographic Details
Main Authors: Afzal, Asif, A. D., Mohammad Samee, R. K., Abdul Razzak, Khan, Sher Afghan, Khan, Hurmatulla
Format: Article
Language:English
English
Published: The Korean Society of Mechanical Engineers 2020
Subjects:
Online Access:http://irep.iium.edu.my/77825/
http://irep.iium.edu.my/77825/
http://irep.iium.edu.my/77825/
http://irep.iium.edu.my/77825/1/77825_Optimum%20spacing%20between%20grooved%20tubes.pdf
http://irep.iium.edu.my/77825/2/77825_Optimum%20spacing%20between%20grooved%20tubes_SCOPUS.pdf
id iium-77825
recordtype eprints
spelling iium-778252020-01-28T08:23:38Z http://irep.iium.edu.my/77825/ Optimum spacing between grooved tubes: an experimental study Afzal, Asif A. D., Mohammad Samee R. K., Abdul Razzak Khan, Sher Afghan Khan, Hurmatulla TJ Mechanical engineering and machinery An experimental study on the optimum spacing between grooved tubes is reported in this paper. Two grooved tubes having a pitch of 10 mm and 15 mm and a plain tube were considered for the heat transfer analysis. The spacing between two tubes with the same pitch was varied from 10 mm to 35 mm with a step size of 5 mm. The velocity of air flowing over the tube surfaces was changed from 0.4 m/s to 1 m/s using a blower fan. Based on Nusselt number (Nu) the optimum spacing between the tubes was decided. The optimum spacing between grooved tubes of pitch 10 mm and 15 mm was compared with that of plain tubes. From the experimental analysis, it was noticed that with an increase in air velocity (increase in Reynolds number) the tube surface temperature reduced irrespective of any tube considered. Nu increased with an increase in air velocity for all the tubes. The important conclusion drawn from the present study was that there exists a limiting spacing (optimum) between the tubes above which no change in Nu was observed. The spacing of 30 mm was found to be the optimum spacing between the tubes irrespective of its surface geometry modifications. The Korean Society of Mechanical Engineers 2020-01-02 Article PeerReviewed application/pdf en http://irep.iium.edu.my/77825/1/77825_Optimum%20spacing%20between%20grooved%20tubes.pdf application/pdf en http://irep.iium.edu.my/77825/2/77825_Optimum%20spacing%20between%20grooved%20tubes_SCOPUS.pdf Afzal, Asif and A. D., Mohammad Samee and R. K., Abdul Razzak and Khan, Sher Afghan and Khan, Hurmatulla (2020) Optimum spacing between grooved tubes: an experimental study. Journal of Mechanical Science and Technology, 34 (1). pp. 469-475. ISSN 1226-4865 https://link.springer.com/article/10.1007%2Fs12206-019-1244-7 10.1007/s12206-019-1244-7
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Afzal, Asif
A. D., Mohammad Samee
R. K., Abdul Razzak
Khan, Sher Afghan
Khan, Hurmatulla
Optimum spacing between grooved tubes: an experimental study
description An experimental study on the optimum spacing between grooved tubes is reported in this paper. Two grooved tubes having a pitch of 10 mm and 15 mm and a plain tube were considered for the heat transfer analysis. The spacing between two tubes with the same pitch was varied from 10 mm to 35 mm with a step size of 5 mm. The velocity of air flowing over the tube surfaces was changed from 0.4 m/s to 1 m/s using a blower fan. Based on Nusselt number (Nu) the optimum spacing between the tubes was decided. The optimum spacing between grooved tubes of pitch 10 mm and 15 mm was compared with that of plain tubes. From the experimental analysis, it was noticed that with an increase in air velocity (increase in Reynolds number) the tube surface temperature reduced irrespective of any tube considered. Nu increased with an increase in air velocity for all the tubes. The important conclusion drawn from the present study was that there exists a limiting spacing (optimum) between the tubes above which no change in Nu was observed. The spacing of 30 mm was found to be the optimum spacing between the tubes irrespective of its surface geometry modifications.
format Article
author Afzal, Asif
A. D., Mohammad Samee
R. K., Abdul Razzak
Khan, Sher Afghan
Khan, Hurmatulla
author_facet Afzal, Asif
A. D., Mohammad Samee
R. K., Abdul Razzak
Khan, Sher Afghan
Khan, Hurmatulla
author_sort Afzal, Asif
title Optimum spacing between grooved tubes: an experimental study
title_short Optimum spacing between grooved tubes: an experimental study
title_full Optimum spacing between grooved tubes: an experimental study
title_fullStr Optimum spacing between grooved tubes: an experimental study
title_full_unstemmed Optimum spacing between grooved tubes: an experimental study
title_sort optimum spacing between grooved tubes: an experimental study
publisher The Korean Society of Mechanical Engineers
publishDate 2020
url http://irep.iium.edu.my/77825/
http://irep.iium.edu.my/77825/
http://irep.iium.edu.my/77825/
http://irep.iium.edu.my/77825/1/77825_Optimum%20spacing%20between%20grooved%20tubes.pdf
http://irep.iium.edu.my/77825/2/77825_Optimum%20spacing%20between%20grooved%20tubes_SCOPUS.pdf
first_indexed 2023-09-18T21:49:43Z
last_indexed 2023-09-18T21:49:43Z
_version_ 1777413687717396480