The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging

The stability of tear film can be measured by tear film break-up time (TFBUT). To date, the comparison value of TFBUT between slit lamp with stopwatch, which is conventional method and anterior segment digital imaging (ASDI) is under explored. The aim of this study was to compare TFBUT value between...

Full description

Bibliographic Details
Main Authors: Abdullah, Noor Afuza, Ithnin, Mohd. Hafidz, Hilmi, Mohd Radzi
Format: Article
Language:English
Published: Management Science University (MSU) 2019
Subjects:
Online Access:http://irep.iium.edu.my/77602/
http://irep.iium.edu.my/77602/1/The%20Comparison%20of%20Measuring%20Tear%20Film%20Break-up%20Time%20Using%20Conventional%20Slit%20Lamp%20Biomicroscopy%20and%20Anterior%20Segment%20Digital%20Imaging.pdf
id iium-77602
recordtype eprints
spelling iium-776022020-01-09T07:19:48Z http://irep.iium.edu.my/77602/ The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging Abdullah, Noor Afuza Ithnin, Mohd. Hafidz Hilmi, Mohd Radzi RE Ophthalmology The stability of tear film can be measured by tear film break-up time (TFBUT). To date, the comparison value of TFBUT between slit lamp with stopwatch, which is conventional method and anterior segment digital imaging (ASDI) is under explored. The aim of this study was to compare TFBUT value between the conventional method and the ASDI utilizing iPhone 6s® video recorder. A total of 20 normal and healthy participants with 40 eyes were involved in this study. Right and left eyes from an individual were considered separately. Three measurements of TFBUT were taken from each methods and average were calculated and recorded. Mann Whitney U test was used to analyze the data and it was found that the median of the TFBUT measurement from the conventional method (2.16 seconds) was higher than the median from the ASDI (2.00 seconds). The comparison between two methods was not significant (p > 0.05). In conclusion, this study suggested that both methods could not give different result in the assessment of TFBUT. Management Science University (MSU) 2019-12-17 Article PeerReviewed application/pdf en http://irep.iium.edu.my/77602/1/The%20Comparison%20of%20Measuring%20Tear%20Film%20Break-up%20Time%20Using%20Conventional%20Slit%20Lamp%20Biomicroscopy%20and%20Anterior%20Segment%20Digital%20Imaging.pdf Abdullah, Noor Afuza and Ithnin, Mohd. Hafidz and Hilmi, Mohd Radzi (2019) The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging. Journal of Optometry, Eye and Health Research (JOEHR), 1 (1). E-ISSN 2682-7859
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Abdullah, Noor Afuza
Ithnin, Mohd. Hafidz
Hilmi, Mohd Radzi
The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging
description The stability of tear film can be measured by tear film break-up time (TFBUT). To date, the comparison value of TFBUT between slit lamp with stopwatch, which is conventional method and anterior segment digital imaging (ASDI) is under explored. The aim of this study was to compare TFBUT value between the conventional method and the ASDI utilizing iPhone 6s® video recorder. A total of 20 normal and healthy participants with 40 eyes were involved in this study. Right and left eyes from an individual were considered separately. Three measurements of TFBUT were taken from each methods and average were calculated and recorded. Mann Whitney U test was used to analyze the data and it was found that the median of the TFBUT measurement from the conventional method (2.16 seconds) was higher than the median from the ASDI (2.00 seconds). The comparison between two methods was not significant (p > 0.05). In conclusion, this study suggested that both methods could not give different result in the assessment of TFBUT.
format Article
author Abdullah, Noor Afuza
Ithnin, Mohd. Hafidz
Hilmi, Mohd Radzi
author_facet Abdullah, Noor Afuza
Ithnin, Mohd. Hafidz
Hilmi, Mohd Radzi
author_sort Abdullah, Noor Afuza
title The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging
title_short The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging
title_full The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging
title_fullStr The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging
title_full_unstemmed The Comparison of Measuring Tear Film Break-up Time Using Conventional Slit Lamp Biomicroscopy and Anterior Segment Digital Imaging
title_sort comparison of measuring tear film break-up time using conventional slit lamp biomicroscopy and anterior segment digital imaging
publisher Management Science University (MSU)
publishDate 2019
url http://irep.iium.edu.my/77602/
http://irep.iium.edu.my/77602/1/The%20Comparison%20of%20Measuring%20Tear%20Film%20Break-up%20Time%20Using%20Conventional%20Slit%20Lamp%20Biomicroscopy%20and%20Anterior%20Segment%20Digital%20Imaging.pdf
first_indexed 2023-09-18T21:49:27Z
last_indexed 2023-09-18T21:49:27Z
_version_ 1777413670873071616