Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)

Portable Eye Examination Kit retina (Peek Retina™, Peek Vision Ltd, UK) and 3D Printed Ophthalmoscope (3DPO) were identified to have acceptable image for retinal evaluation, however the retinal images quality in term of blood vessels visibility between both devices was uncertain. This study was co...

Full description

Bibliographic Details
Main Authors: Esa, Nur Raihan, Yusof, Firdaus, Che Azemin, Mohd Zulfaezal, Ahmad, Norsham, Mohd Shukri, Nor Azwani
Format: Article
Language:English
English
Published: Blue Eyes Intelligence Engineering & Sciences Publication 2019
Subjects:
Online Access:http://irep.iium.edu.my/74699/
http://irep.iium.edu.my/74699/
http://irep.iium.edu.my/74699/
http://irep.iium.edu.my/74699/7/74699%20Retinal%20Image%20Quality%20Assessment.pdf
http://irep.iium.edu.my/74699/8/74699%20Retinal%20Image%20Quality%20Assessment%20SCOPUS.pdf
id iium-74699
recordtype eprints
spelling iium-746992019-10-17T02:15:17Z http://irep.iium.edu.my/74699/ Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo) Esa, Nur Raihan Yusof, Firdaus Che Azemin, Mohd Zulfaezal Ahmad, Norsham Mohd Shukri, Nor Azwani RE Ophthalmology Portable Eye Examination Kit retina (Peek Retina™, Peek Vision Ltd, UK) and 3D Printed Ophthalmoscope (3DPO) were identified to have acceptable image for retinal evaluation, however the retinal images quality in term of blood vessels visibility between both devices was uncertain. This study was conducted to compare the quality of image based on blood vessels visibility between Peek Retina and 3DPO for fractal dimension (Df) analysis. In this study, a total of 40 retinal images (nPEEK=20, n3DPO=20) of 20 participants were captured on random eyes. The best retinal images with good focus and significant retinal blood vessels visibility of Peek Retina and 3DPO were selected for image quality analysis. The retinal images were cropped approximately following the size of the cornea and resized to 900 by 900 pixels of resolution using GNU Image Manipulation Program Version 2.8.18 (GIMP). The images were randomly sorted as Retinal Image Quality Assessment (RIQA) generated by Google form. Likert scale was implemented to assess the preferences scale of retinal image quality in determining the visibility of retinal vasculature to be traced with four choices of response options (1; very difficult, 2; difficult, 3; easy and 4; very easy). Prior to the retinal image assessment, ten optometrists were asked to experience retinal blood vessels tracing and consequently evaluate the 40 images by choosing the scale options (1 to 4) based on visibility retinal blood vessels. Mann-Whitney test indicated that the blood vessel tracing was easier for Peek Retina (median = 3) than for 3DPO (median = 2), p < 0.0001. Retinal image captured by Peek Retina was rated as very easy (43.5%) for blood vessels tracing as compared to the image from 3DPO (17.0%)Error! Reference source not found.. Only 1.5% of the image captured by PEEK was considered as a very difficult for blood vessel tracing. Difficult and easy preference scales of blood vessel tracing for PEEK were 16.5% and 38.5% respectively. 34% of 3DPO retinal image was graded as difficult for blood vessel tracing followed by 28.5% (easy), 20.5% (very difficult) and 17.0% (very easy). The results indicate that a retinal image photographed by Peek Retina was more preferable in tracing retinal vascular network for Df analysis as compared to 3DPO. Blue Eyes Intelligence Engineering & Sciences Publication 2019-07 Article PeerReviewed application/pdf en http://irep.iium.edu.my/74699/7/74699%20Retinal%20Image%20Quality%20Assessment.pdf application/pdf en http://irep.iium.edu.my/74699/8/74699%20Retinal%20Image%20Quality%20Assessment%20SCOPUS.pdf Esa, Nur Raihan and Yusof, Firdaus and Che Azemin, Mohd Zulfaezal and Ahmad, Norsham and Mohd Shukri, Nor Azwani (2019) Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo). International Journal of Innovative Technology and Exploring Engineering, 8 (9S3). pp. 1555-1559. E-ISSN 2278-3075 https://www.ijitee.org/wp-content/uploads/papers/v8i9S3/I33250789S319.pdf 10.35940/ijitee.I3325.0789S319
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Esa, Nur Raihan
Yusof, Firdaus
Che Azemin, Mohd Zulfaezal
Ahmad, Norsham
Mohd Shukri, Nor Azwani
Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)
description Portable Eye Examination Kit retina (Peek Retina™, Peek Vision Ltd, UK) and 3D Printed Ophthalmoscope (3DPO) were identified to have acceptable image for retinal evaluation, however the retinal images quality in term of blood vessels visibility between both devices was uncertain. This study was conducted to compare the quality of image based on blood vessels visibility between Peek Retina and 3DPO for fractal dimension (Df) analysis. In this study, a total of 40 retinal images (nPEEK=20, n3DPO=20) of 20 participants were captured on random eyes. The best retinal images with good focus and significant retinal blood vessels visibility of Peek Retina and 3DPO were selected for image quality analysis. The retinal images were cropped approximately following the size of the cornea and resized to 900 by 900 pixels of resolution using GNU Image Manipulation Program Version 2.8.18 (GIMP). The images were randomly sorted as Retinal Image Quality Assessment (RIQA) generated by Google form. Likert scale was implemented to assess the preferences scale of retinal image quality in determining the visibility of retinal vasculature to be traced with four choices of response options (1; very difficult, 2; difficult, 3; easy and 4; very easy). Prior to the retinal image assessment, ten optometrists were asked to experience retinal blood vessels tracing and consequently evaluate the 40 images by choosing the scale options (1 to 4) based on visibility retinal blood vessels. Mann-Whitney test indicated that the blood vessel tracing was easier for Peek Retina (median = 3) than for 3DPO (median = 2), p < 0.0001. Retinal image captured by Peek Retina was rated as very easy (43.5%) for blood vessels tracing as compared to the image from 3DPO (17.0%)Error! Reference source not found.. Only 1.5% of the image captured by PEEK was considered as a very difficult for blood vessel tracing. Difficult and easy preference scales of blood vessel tracing for PEEK were 16.5% and 38.5% respectively. 34% of 3DPO retinal image was graded as difficult for blood vessel tracing followed by 28.5% (easy), 20.5% (very difficult) and 17.0% (very easy). The results indicate that a retinal image photographed by Peek Retina was more preferable in tracing retinal vascular network for Df analysis as compared to 3DPO.
format Article
author Esa, Nur Raihan
Yusof, Firdaus
Che Azemin, Mohd Zulfaezal
Ahmad, Norsham
Mohd Shukri, Nor Azwani
author_facet Esa, Nur Raihan
Yusof, Firdaus
Che Azemin, Mohd Zulfaezal
Ahmad, Norsham
Mohd Shukri, Nor Azwani
author_sort Esa, Nur Raihan
title Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)
title_short Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)
title_full Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)
title_fullStr Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)
title_full_unstemmed Retinal image quality assessment: Portable eye examination kit retina (Peek Retina)™ versus 3d-printed ophthalmoscope (3dpo)
title_sort retinal image quality assessment: portable eye examination kit retina (peek retina)™ versus 3d-printed ophthalmoscope (3dpo)
publisher Blue Eyes Intelligence Engineering & Sciences Publication
publishDate 2019
url http://irep.iium.edu.my/74699/
http://irep.iium.edu.my/74699/
http://irep.iium.edu.my/74699/
http://irep.iium.edu.my/74699/7/74699%20Retinal%20Image%20Quality%20Assessment.pdf
http://irep.iium.edu.my/74699/8/74699%20Retinal%20Image%20Quality%20Assessment%20SCOPUS.pdf
first_indexed 2023-09-18T21:45:43Z
last_indexed 2023-09-18T21:45:43Z
_version_ 1777413436089565184