Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
Purpose: This study was aimed to evaluate the tear lipid floating time (LFT) using dynamic fluorescein test. Method: Three hundred and twenty-one subjects with 642 eyes were included in this cross-sectional study. A subject was considered having dry eye if the tear film break-up time (TFBUT) and...
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
2019
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/73575/ http://irep.iium.edu.my/73575/ http://irep.iium.edu.my/73575/8/73575%20Programme%20book.pdf http://irep.iium.edu.my/73575/1/Poster%20Assessment%20of%20Clinical%20Tear%20Lipid%20Floating%20Time%20Utilizing%20Dynamic%20Fluorescein%20Test.pdf |
id |
iium-73575 |
---|---|
recordtype |
eprints |
spelling |
iium-735752020-01-03T03:25:19Z http://irep.iium.edu.my/73575/ Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test Ithnin, Mohd. Hafidz Ariffin, Azrin Esmady Mohd Kamal, Khairidzan RE Ophthalmology Purpose: This study was aimed to evaluate the tear lipid floating time (LFT) using dynamic fluorescein test. Method: Three hundred and twenty-one subjects with 642 eyes were included in this cross-sectional study. A subject was considered having dry eye if the tear film break-up time (TFBUT) and schirmer test with anaesthesia values were less than 5 seconds and 5mm/5 minutes respectively. A fluorescein strip was wetted and instilled on each eye. The spreading particle with oily texture of tear film is considered as lipid floating and the duration of movement was taken until it stabilized. The assessment was conducted using slit lamp videographer. Results: The mean of LFT was 1.65 ± 0.85 seconds. The mean of LFT among non-dry eye group was 1.70 ± 0.90 seconds while 1.60 ± 0.80 seconds for dry eye. No significant different was found between both groups (p > 0.05). Conclusion: The dynamic of lipid floating can be assessed utilizing clinical technique which is fluorescein dynamic test. However, the floating time of lipid between non-dry and dry eye was almost identical. 2019 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/73575/8/73575%20Programme%20book.pdf application/pdf en http://irep.iium.edu.my/73575/1/Poster%20Assessment%20of%20Clinical%20Tear%20Lipid%20Floating%20Time%20Utilizing%20Dynamic%20Fluorescein%20Test.pdf Ithnin, Mohd. Hafidz and Ariffin, Azrin Esmady and Mohd Kamal, Khairidzan (2019) Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test. In: The 10th MSO Annual Scientific Meeting in conjunction with the 34th Malaysia-Singapore Joint Ophthalmic Congress Secretariat, 22nd-24th March 2019, Kuantan, Pahang. (Unpublished) https://www.mso.org.my/index.cfm?menuid=112 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
RE Ophthalmology |
spellingShingle |
RE Ophthalmology Ithnin, Mohd. Hafidz Ariffin, Azrin Esmady Mohd Kamal, Khairidzan Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
description |
Purpose: This study was aimed to evaluate the tear lipid floating time (LFT) using dynamic fluorescein test.
Method: Three hundred and twenty-one subjects with 642 eyes were included in this cross-sectional study. A subject was considered having dry eye if the tear film break-up time (TFBUT) and schirmer test with anaesthesia values were less than 5 seconds and 5mm/5 minutes respectively. A fluorescein strip was wetted and instilled on each eye. The spreading particle with oily texture of tear film is considered as lipid floating and the duration of movement was taken until it stabilized. The assessment was conducted using slit lamp videographer.
Results: The mean of LFT was 1.65 ± 0.85 seconds. The mean of LFT among non-dry eye group was 1.70 ± 0.90 seconds while 1.60 ± 0.80 seconds for dry eye. No significant different was found between both groups (p > 0.05).
Conclusion: The dynamic of lipid floating can be assessed utilizing clinical technique which is fluorescein dynamic test. However, the floating time of lipid between non-dry and dry eye was almost identical. |
format |
Conference or Workshop Item |
author |
Ithnin, Mohd. Hafidz Ariffin, Azrin Esmady Mohd Kamal, Khairidzan |
author_facet |
Ithnin, Mohd. Hafidz Ariffin, Azrin Esmady Mohd Kamal, Khairidzan |
author_sort |
Ithnin, Mohd. Hafidz |
title |
Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
title_short |
Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
title_full |
Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
title_fullStr |
Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
title_full_unstemmed |
Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
title_sort |
assessment of clinical tear lipid floating time utilizing dynamic fluorescein test |
publishDate |
2019 |
url |
http://irep.iium.edu.my/73575/ http://irep.iium.edu.my/73575/ http://irep.iium.edu.my/73575/8/73575%20Programme%20book.pdf http://irep.iium.edu.my/73575/1/Poster%20Assessment%20of%20Clinical%20Tear%20Lipid%20Floating%20Time%20Utilizing%20Dynamic%20Fluorescein%20Test.pdf |
first_indexed |
2023-09-18T21:44:18Z |
last_indexed |
2023-09-18T21:44:18Z |
_version_ |
1777413347339141120 |