Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test

Purpose: This study was aimed to evaluate the tear lipid floating time (LFT) using dynamic fluorescein test. Method: Three hundred and twenty-one subjects with 642 eyes were included in this cross-sectional study. A subject was considered having dry eye if the tear film break-up time (TFBUT) and...

Full description

Bibliographic Details
Main Authors: Ithnin, Mohd. Hafidz, Ariffin, Azrin Esmady, Mohd Kamal, Khairidzan
Format: Conference or Workshop Item
Language:English
English
Published: 2019
Subjects:
Online Access:http://irep.iium.edu.my/73575/
http://irep.iium.edu.my/73575/
http://irep.iium.edu.my/73575/8/73575%20Programme%20book.pdf
http://irep.iium.edu.my/73575/1/Poster%20Assessment%20of%20Clinical%20Tear%20Lipid%20Floating%20Time%20Utilizing%20Dynamic%20Fluorescein%20Test.pdf
id iium-73575
recordtype eprints
spelling iium-735752020-01-03T03:25:19Z http://irep.iium.edu.my/73575/ Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test Ithnin, Mohd. Hafidz Ariffin, Azrin Esmady Mohd Kamal, Khairidzan RE Ophthalmology Purpose: This study was aimed to evaluate the tear lipid floating time (LFT) using dynamic fluorescein test. Method: Three hundred and twenty-one subjects with 642 eyes were included in this cross-sectional study. A subject was considered having dry eye if the tear film break-up time (TFBUT) and schirmer test with anaesthesia values were less than 5 seconds and 5mm/5 minutes respectively. A fluorescein strip was wetted and instilled on each eye. The spreading particle with oily texture of tear film is considered as lipid floating and the duration of movement was taken until it stabilized. The assessment was conducted using slit lamp videographer. Results: The mean of LFT was 1.65 ± 0.85 seconds. The mean of LFT among non-dry eye group was 1.70 ± 0.90 seconds while 1.60 ± 0.80 seconds for dry eye. No significant different was found between both groups (p > 0.05). Conclusion: The dynamic of lipid floating can be assessed utilizing clinical technique which is fluorescein dynamic test. However, the floating time of lipid between non-dry and dry eye was almost identical. 2019 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/73575/8/73575%20Programme%20book.pdf application/pdf en http://irep.iium.edu.my/73575/1/Poster%20Assessment%20of%20Clinical%20Tear%20Lipid%20Floating%20Time%20Utilizing%20Dynamic%20Fluorescein%20Test.pdf Ithnin, Mohd. Hafidz and Ariffin, Azrin Esmady and Mohd Kamal, Khairidzan (2019) Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test. In: The 10th MSO Annual Scientific Meeting in conjunction with the 34th Malaysia-Singapore Joint Ophthalmic Congress Secretariat, 22nd-24th March 2019, Kuantan, Pahang. (Unpublished) https://www.mso.org.my/index.cfm?menuid=112
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic RE Ophthalmology
spellingShingle RE Ophthalmology
Ithnin, Mohd. Hafidz
Ariffin, Azrin Esmady
Mohd Kamal, Khairidzan
Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
description Purpose: This study was aimed to evaluate the tear lipid floating time (LFT) using dynamic fluorescein test. Method: Three hundred and twenty-one subjects with 642 eyes were included in this cross-sectional study. A subject was considered having dry eye if the tear film break-up time (TFBUT) and schirmer test with anaesthesia values were less than 5 seconds and 5mm/5 minutes respectively. A fluorescein strip was wetted and instilled on each eye. The spreading particle with oily texture of tear film is considered as lipid floating and the duration of movement was taken until it stabilized. The assessment was conducted using slit lamp videographer. Results: The mean of LFT was 1.65 ± 0.85 seconds. The mean of LFT among non-dry eye group was 1.70 ± 0.90 seconds while 1.60 ± 0.80 seconds for dry eye. No significant different was found between both groups (p > 0.05). Conclusion: The dynamic of lipid floating can be assessed utilizing clinical technique which is fluorescein dynamic test. However, the floating time of lipid between non-dry and dry eye was almost identical.
format Conference or Workshop Item
author Ithnin, Mohd. Hafidz
Ariffin, Azrin Esmady
Mohd Kamal, Khairidzan
author_facet Ithnin, Mohd. Hafidz
Ariffin, Azrin Esmady
Mohd Kamal, Khairidzan
author_sort Ithnin, Mohd. Hafidz
title Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
title_short Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
title_full Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
title_fullStr Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
title_full_unstemmed Assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
title_sort assessment of clinical tear lipid floating time utilizing dynamic fluorescein test
publishDate 2019
url http://irep.iium.edu.my/73575/
http://irep.iium.edu.my/73575/
http://irep.iium.edu.my/73575/8/73575%20Programme%20book.pdf
http://irep.iium.edu.my/73575/1/Poster%20Assessment%20of%20Clinical%20Tear%20Lipid%20Floating%20Time%20Utilizing%20Dynamic%20Fluorescein%20Test.pdf
first_indexed 2023-09-18T21:44:18Z
last_indexed 2023-09-18T21:44:18Z
_version_ 1777413347339141120