Simulation and fabrication of micro magnetometer using flip-chip bonding technique
Magnetic field detection has been widely accepted in many applications such as military systems, outer space exploration and even in medical diagnosis and treatment. Low magnetic field detection is particularly important in tracking of magnetic markers in digestive tracks or blood vessels. The pr...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
Springer Nature Singapore Pte Ltd.
2019
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/73199/ http://irep.iium.edu.my/73199/ http://irep.iium.edu.my/73199/ http://irep.iium.edu.my/73199/1/73199_Simulation%20and%20fabrication%20of%20micro%20magnetometer.pdf http://irep.iium.edu.my/73199/7/73199_Simulation%20and%20fabrication%20of%20micro%20magnetometer%20using%20flip-chip%20bonding%20technique_scopus.pdf |
id |
iium-73199 |
---|---|
recordtype |
eprints |
spelling |
iium-731992019-10-16T09:24:00Z http://irep.iium.edu.my/73199/ Simulation and fabrication of micro magnetometer using flip-chip bonding technique Tengku Azmi, Tengku Muhammad Afif Sulaiman, Nadzril T Technology (General) TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Magnetic field detection has been widely accepted in many applications such as military systems, outer space exploration and even in medical diagnosis and treatment. Low magnetic field detection is particularly important in tracking of magnetic markers in digestive tracks or blood vessels. The presence of magnetic fields’ strength and direction can be detected by a device known as magnetometer. A magnetometer that is durable, room temperature operation and having non-movable components is chooses for this project. Traditional magnetometer tends to be bulky that hinders its inclusion into micro-scaled environment. This concern has brought the magnetometer into the trend of device miniaturization. Miniaturized magnetometer is usually fabricated using conventional microfabrication method particularly surface micromachining in which micro structures are built level by level starting from the surface of substrates upwards until completion of final structure. Although the miniaturization of magnetometer has been widely researched and studied, the process however is not. Thus, the process governing the fabrication technique is studied in this paper. Conventional method of fabrication is known as surface micromachining. Besides time consuming, this method requires many consecutive steps in fabrication process and careful alignment of patterns on every layer which increase the complexity. Hence, studies are done to improve time consuming and reliability of the microfabrication process. The objective of this research includes designing micro scale magnetometer and complete device fabrication processes. A micro-scale search coil magnetometer of 15 windings with 600μm thickness of wire and 300μm distance between each wire has been designed. Springer Nature Singapore Pte Ltd. Alfred, Rayner Ag Ibrahim, Ag Asri Lim, Yuto Anthony, Patricia 2019 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/73199/1/73199_Simulation%20and%20fabrication%20of%20micro%20magnetometer.pdf application/pdf en http://irep.iium.edu.my/73199/7/73199_Simulation%20and%20fabrication%20of%20micro%20magnetometer%20using%20flip-chip%20bonding%20technique_scopus.pdf Tengku Azmi, Tengku Muhammad Afif and Sulaiman, Nadzril (2019) Simulation and fabrication of micro magnetometer using flip-chip bonding technique. In: 5th International Conference on Computational Science and Technology, ICCST 2018, 29-30 Aug 2018, Kota Kinabalu. https://link.springer.com/chapter/10.1007/978-981-13-2622-6_48 https://doi.org/10.1007/978-981-13-2622-6 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
T Technology (General) TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices |
spellingShingle |
T Technology (General) TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Tengku Azmi, Tengku Muhammad Afif Sulaiman, Nadzril Simulation and fabrication of micro magnetometer using flip-chip bonding technique |
description |
Magnetic field detection has been widely accepted in many applications
such as military systems, outer space exploration and even in medical diagnosis
and treatment. Low magnetic field detection is particularly important in
tracking of magnetic markers in digestive tracks or blood vessels. The presence
of magnetic fields’ strength and direction can be detected by a device known as
magnetometer. A magnetometer that is durable, room temperature operation
and having non-movable components is chooses for this project. Traditional
magnetometer tends to be bulky that hinders its inclusion into micro-scaled environment.
This concern has brought the magnetometer into the trend of device
miniaturization. Miniaturized magnetometer is usually fabricated using conventional
microfabrication method particularly surface micromachining in which
micro structures are built level by level starting from the surface of substrates
upwards until completion of final structure. Although the miniaturization of
magnetometer has been widely researched and studied, the process however is
not. Thus, the process governing the fabrication technique is studied in this paper.
Conventional method of fabrication is known as surface micromachining.
Besides time consuming, this method requires many consecutive steps in fabrication
process and careful alignment of patterns on every layer which increase
the complexity. Hence, studies are done to improve time consuming and reliability
of the microfabrication process. The objective of this research includes
designing micro scale magnetometer and complete device fabrication processes.
A micro-scale search coil magnetometer of 15 windings with 600μm thickness
of wire and 300μm distance between each wire has been designed. |
author2 |
Alfred, Rayner |
author_facet |
Alfred, Rayner Tengku Azmi, Tengku Muhammad Afif Sulaiman, Nadzril |
format |
Conference or Workshop Item |
author |
Tengku Azmi, Tengku Muhammad Afif Sulaiman, Nadzril |
author_sort |
Tengku Azmi, Tengku Muhammad Afif |
title |
Simulation and fabrication of micro magnetometer
using flip-chip bonding technique |
title_short |
Simulation and fabrication of micro magnetometer
using flip-chip bonding technique |
title_full |
Simulation and fabrication of micro magnetometer
using flip-chip bonding technique |
title_fullStr |
Simulation and fabrication of micro magnetometer
using flip-chip bonding technique |
title_full_unstemmed |
Simulation and fabrication of micro magnetometer
using flip-chip bonding technique |
title_sort |
simulation and fabrication of micro magnetometer
using flip-chip bonding technique |
publisher |
Springer Nature Singapore Pte Ltd. |
publishDate |
2019 |
url |
http://irep.iium.edu.my/73199/ http://irep.iium.edu.my/73199/ http://irep.iium.edu.my/73199/ http://irep.iium.edu.my/73199/1/73199_Simulation%20and%20fabrication%20of%20micro%20magnetometer.pdf http://irep.iium.edu.my/73199/7/73199_Simulation%20and%20fabrication%20of%20micro%20magnetometer%20using%20flip-chip%20bonding%20technique_scopus.pdf |
first_indexed |
2023-09-18T21:43:47Z |
last_indexed |
2023-09-18T21:43:47Z |
_version_ |
1777413314789244928 |