Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller
The aim of this project is to evaluate the dynamic process performance of SE113 Flow Control System Plant using self-tuning Fuzzy PI controller. The experimental data is used to model the process and the control analysis is done using Self-Tuning Fuzzy PI Controller. The performance evaluation is ba...
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2018
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/71848/ http://irep.iium.edu.my/71848/ http://irep.iium.edu.my/71848/1/71848_Performance%20Evaluation%20for%20SE113%20Flow.pdf http://irep.iium.edu.my/71848/7/71848_Performance%20evaluation%20for%20SE113_scopus.pdf |
id |
iium-71848 |
---|---|
recordtype |
eprints |
spelling |
iium-718482019-07-15T03:45:16Z http://irep.iium.edu.my/71848/ Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller Janin, Zuriati Sam, Rosida Masrie, Marianah Abdul Kadir, Kushsairy Mohamad Hanif, Noor Hazrin Hany Gunawan, Teddy Surya TJ212 Control engineering TK Electrical engineering. Electronics Nuclear engineering The aim of this project is to evaluate the dynamic process performance of SE113 Flow Control System Plant using self-tuning Fuzzy PI controller. The experimental data is used to model the process and the control analysis is done using Self-Tuning Fuzzy PI Controller. The performance evaluation is based on the percent overshoot, rise time and settling time of the process. The overall performance is compared with the conventional Proportional-Integral control method. The results had shown that self-tuning Fuzzy PI controller simplify the tediousness in tuning the controller and enhance the capability of PI controller. Institute of Electrical and Electronics Engineers Inc. 2018-11-28 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/71848/1/71848_Performance%20Evaluation%20for%20SE113%20Flow.pdf application/pdf en http://irep.iium.edu.my/71848/7/71848_Performance%20evaluation%20for%20SE113_scopus.pdf Janin, Zuriati and Sam, Rosida and Masrie, Marianah and Abdul Kadir, Kushsairy and Mohamad Hanif, Noor Hazrin Hany and Gunawan, Teddy Surya (2018) Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller. In: 2018 IEEE 5th International Conference on Smart Instrumentation, Measurement and Application (ICSIMA), 28th-30th Nov 2018, Songkla, Thailand. https://ieeexplore.ieee.org/document/8688799 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
TJ212 Control engineering TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TJ212 Control engineering TK Electrical engineering. Electronics Nuclear engineering Janin, Zuriati Sam, Rosida Masrie, Marianah Abdul Kadir, Kushsairy Mohamad Hanif, Noor Hazrin Hany Gunawan, Teddy Surya Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller |
description |
The aim of this project is to evaluate the dynamic process performance of SE113 Flow Control System Plant using self-tuning Fuzzy PI controller. The experimental data is used to model the process and the control analysis is done using Self-Tuning Fuzzy PI Controller. The performance evaluation is based on the percent overshoot, rise time and settling time of the process.
The overall performance is compared with the conventional
Proportional-Integral control method. The results had shown that self-tuning Fuzzy PI controller simplify the tediousness in tuning the controller and enhance the capability of PI controller. |
format |
Conference or Workshop Item |
author |
Janin, Zuriati Sam, Rosida Masrie, Marianah Abdul Kadir, Kushsairy Mohamad Hanif, Noor Hazrin Hany Gunawan, Teddy Surya |
author_facet |
Janin, Zuriati Sam, Rosida Masrie, Marianah Abdul Kadir, Kushsairy Mohamad Hanif, Noor Hazrin Hany Gunawan, Teddy Surya |
author_sort |
Janin, Zuriati |
title |
Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller |
title_short |
Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller |
title_full |
Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller |
title_fullStr |
Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller |
title_full_unstemmed |
Performance evaluation for SE113 flow control system plant using self-tuning fuzzy PI controller |
title_sort |
performance evaluation for se113 flow control system plant using self-tuning fuzzy pi controller |
publisher |
Institute of Electrical and Electronics Engineers Inc. |
publishDate |
2018 |
url |
http://irep.iium.edu.my/71848/ http://irep.iium.edu.my/71848/ http://irep.iium.edu.my/71848/1/71848_Performance%20Evaluation%20for%20SE113%20Flow.pdf http://irep.iium.edu.my/71848/7/71848_Performance%20evaluation%20for%20SE113_scopus.pdf |
first_indexed |
2023-09-18T21:41:52Z |
last_indexed |
2023-09-18T21:41:52Z |
_version_ |
1777413193784623104 |