Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications
This paper proposes a carrier-based pulse width modulation (CB-PWM) method with synchronous switching technique for a Vienna rectifier. In this paper, a Vienna rectifier is one of the 3-level converter topologies. It is similar to a 3-level T-type topology the used back-to-back switches. When CB-PWM...
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
IEEE Explore
2018
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/67819/ http://irep.iium.edu.my/67819/ http://irep.iium.edu.my/67819/1/67819_Carrier%20Based%20Synchronous%20control-paper.pdf http://irep.iium.edu.my/67819/7/67819_Carrier%20Based%20Synchronous%20control-paper_Scopus.pdf |
id |
iium-67819 |
---|---|
recordtype |
eprints |
spelling |
iium-678192019-07-15T03:18:36Z http://irep.iium.edu.my/67819/ Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications Rahman, Tawfikur Motakabber, S. M. A. Ibrahimy, Muhammad Ibn Alam, A. H. M. Zahirul Mostafa, Mohammad Golam Rahman, M. Wahidur T Technology (General) TK5101 Telecommunication. Including telegraphy, radio, radar, television This paper proposes a carrier-based pulse width modulation (CB-PWM) method with synchronous switching technique for a Vienna rectifier. In this paper, a Vienna rectifier is one of the 3-level converter topologies. It is similar to a 3-level T-type topology the used back-to-back switches. When CB-PWM switching method is used, a Vienna rectifier is operated with six PWM signals. On the other hand, when the back-to-back switches are synchronized, PWM signals can be reduced to three from six. However, the synchronous switching method has a problem that the current distortion around zero-crossing point is worse than one of the conventional CB-PWM switching method. To improve current distortions, this paper proposes a reactive current injection technique. The performance and effectiveness of the proposed synchronous switching method are verified by simulation with a 5-kW Vienna rectifier. IEEE Explore 2018 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/67819/1/67819_Carrier%20Based%20Synchronous%20control-paper.pdf application/pdf en http://irep.iium.edu.my/67819/7/67819_Carrier%20Based%20Synchronous%20control-paper_Scopus.pdf Rahman, Tawfikur and Motakabber, S. M. A. and Ibrahimy, Muhammad Ibn and Alam, A. H. M. Zahirul and Mostafa, Mohammad Golam and Rahman, M. Wahidur (2018) Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications. In: 7th International Conference on Computer and Communication Engineering (ICCCE) 2018, 19th-20th September 2018, Kuala Lumpur. https://ieeexplore.ieee.org/document/7951655 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
T Technology (General) TK5101 Telecommunication. Including telegraphy, radio, radar, television |
spellingShingle |
T Technology (General) TK5101 Telecommunication. Including telegraphy, radio, radar, television Rahman, Tawfikur Motakabber, S. M. A. Ibrahimy, Muhammad Ibn Alam, A. H. M. Zahirul Mostafa, Mohammad Golam Rahman, M. Wahidur Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications |
description |
This paper proposes a carrier-based pulse width modulation (CB-PWM) method with synchronous switching technique for a Vienna rectifier. In this paper, a Vienna rectifier is one of the 3-level converter topologies. It is similar to a 3-level T-type topology the used back-to-back switches. When CB-PWM switching method is used, a Vienna rectifier is operated with six PWM signals. On the other hand, when the back-to-back switches are synchronized, PWM signals can be reduced to three from six. However, the synchronous switching method has a problem that the current distortion around zero-crossing point is worse than one of the conventional CB-PWM switching method. To improve current distortions, this paper proposes a reactive current injection technique. The performance and effectiveness of the proposed synchronous switching method are verified by simulation with a 5-kW Vienna rectifier. |
format |
Conference or Workshop Item |
author |
Rahman, Tawfikur Motakabber, S. M. A. Ibrahimy, Muhammad Ibn Alam, A. H. M. Zahirul Mostafa, Mohammad Golam Rahman, M. Wahidur |
author_facet |
Rahman, Tawfikur Motakabber, S. M. A. Ibrahimy, Muhammad Ibn Alam, A. H. M. Zahirul Mostafa, Mohammad Golam Rahman, M. Wahidur |
author_sort |
Rahman, Tawfikur |
title |
Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications |
title_short |
Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications |
title_full |
Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications |
title_fullStr |
Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications |
title_full_unstemmed |
Carrier based synchronous control and performance analysis of an S-PSI using PV for microgrid applications |
title_sort |
carrier based synchronous control and performance analysis of an s-psi using pv for microgrid applications |
publisher |
IEEE Explore |
publishDate |
2018 |
url |
http://irep.iium.edu.my/67819/ http://irep.iium.edu.my/67819/ http://irep.iium.edu.my/67819/1/67819_Carrier%20Based%20Synchronous%20control-paper.pdf http://irep.iium.edu.my/67819/7/67819_Carrier%20Based%20Synchronous%20control-paper_Scopus.pdf |
first_indexed |
2023-09-18T21:36:18Z |
last_indexed |
2023-09-18T21:36:18Z |
_version_ |
1777412843086282752 |