Development of non-contact liquid level measurement and data storage system
The normal contact type liquid measurement devices have some drawbacks since they have potential damage due to the sensor fouling or corrosion since those are continuously exposed to the liquid. Especially flash flood may cause the damage of liquid level sensor. So that, it is important to design a...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
International Journal of Engineering Materials and Manufacture
2018
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/67368/ http://irep.iium.edu.my/67368/ http://irep.iium.edu.my/67368/ http://irep.iium.edu.my/67368/1/Development%20of%20Non-Contact%20Liquid%20Level%20Measurement%20and%20Data%20Storage%20System.pdf |
id |
iium-67368 |
---|---|
recordtype |
eprints |
spelling |
iium-673682018-11-08T06:32:03Z http://irep.iium.edu.my/67368/ Development of non-contact liquid level measurement and data storage system Rashid, Muhammad Mahbubur Al Mamun, Abdullah Jaafar, Abdul Hassan Mollik, Md. Sajib TK301 Electric meters TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices The normal contact type liquid measurement devices have some drawbacks since they have potential damage due to the sensor fouling or corrosion since those are continuously exposed to the liquid. Especially flash flood may cause the damage of liquid level sensor. So that, it is important to design a non-contact device for liquid level measurement in order to avoid this constrain. Distance can be measured without contact such as laser, ultrasonic and radar. In this research, ultrasonic sensor is used to provide non-contact feature of the device since it is low cost and uses ultra-sound waves rather than light. This vital sensing device is able to sense uneven surfaces, liquids, clear objects, and objects in dirty environments. This paper discussed the measurement of liquid level in a tank as well as storing historical data. International Journal of Engineering Materials and Manufacture 2018-09-15 Article PeerReviewed application/pdf en http://irep.iium.edu.my/67368/1/Development%20of%20Non-Contact%20Liquid%20Level%20Measurement%20and%20Data%20Storage%20System.pdf Rashid, Muhammad Mahbubur and Al Mamun, Abdullah and Jaafar, Abdul Hassan and Mollik, Md. Sajib (2018) Development of non-contact liquid level measurement and data storage system. International Journal of Engineering Materials and Manufacture, 3 (3). pp. 134-142. E-ISSN 0128-1852 https://www.deerhillpublishing.com/index.php/ijemm/issue/view/12 doi.org/10.26776/ijemm.03.03.2018.02 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
TK301 Electric meters TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices |
spellingShingle |
TK301 Electric meters TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Rashid, Muhammad Mahbubur Al Mamun, Abdullah Jaafar, Abdul Hassan Mollik, Md. Sajib Development of non-contact liquid level measurement and data storage system |
description |
The normal contact type liquid measurement devices have some drawbacks since they have potential damage due to the sensor fouling or corrosion since those are continuously exposed to the liquid. Especially flash flood may cause the damage of liquid level sensor. So that, it is important to design a non-contact device for liquid level measurement in order to avoid this constrain. Distance can be measured without contact such as laser, ultrasonic and radar. In this research, ultrasonic sensor is used to provide non-contact feature of the device since it is low cost and uses ultra-sound waves rather than light. This vital sensing device is able to sense uneven surfaces, liquids, clear objects, and objects in dirty environments. This paper discussed the measurement of liquid level in a tank as well as storing historical data. |
format |
Article |
author |
Rashid, Muhammad Mahbubur Al Mamun, Abdullah Jaafar, Abdul Hassan Mollik, Md. Sajib |
author_facet |
Rashid, Muhammad Mahbubur Al Mamun, Abdullah Jaafar, Abdul Hassan Mollik, Md. Sajib |
author_sort |
Rashid, Muhammad Mahbubur |
title |
Development of non-contact liquid level measurement and data storage system |
title_short |
Development of non-contact liquid level measurement and data storage system |
title_full |
Development of non-contact liquid level measurement and data storage system |
title_fullStr |
Development of non-contact liquid level measurement and data storage system |
title_full_unstemmed |
Development of non-contact liquid level measurement and data storage system |
title_sort |
development of non-contact liquid level measurement and data storage system |
publisher |
International Journal of Engineering Materials and Manufacture |
publishDate |
2018 |
url |
http://irep.iium.edu.my/67368/ http://irep.iium.edu.my/67368/ http://irep.iium.edu.my/67368/ http://irep.iium.edu.my/67368/1/Development%20of%20Non-Contact%20Liquid%20Level%20Measurement%20and%20Data%20Storage%20System.pdf |
first_indexed |
2023-09-18T21:35:39Z |
last_indexed |
2023-09-18T21:35:39Z |
_version_ |
1777412802952036352 |