Non-contact capacitive technique for biomass flow sensing

To facilitate real-time flow measurement, this paper aims to realize biomass flow sensing through electronic non-contact capacitive means. Hardware implementation has been carried out using a modified OP-AMP-based bridge circuit, with one arm made of a standard capacitance while the other arm is mad...

Full description

Bibliographic Details
Main Authors: Tasnim, Rumana, Khan, Sheroz, Arshad, Atika, Hussein, Molla Rashied
Format: Article
Language:English
English
Published: Institute of Advanced Engineering and Science 2018
Subjects:
Online Access:http://irep.iium.edu.my/64734/
http://irep.iium.edu.my/64734/
http://irep.iium.edu.my/64734/
http://irep.iium.edu.my/64734/1/64734_Non-Contact%20Capacitive%20Technique.pdf
http://irep.iium.edu.my/64734/2/64734_Non-Contact%20Capacitive%20Technique_SCOPUS.pdf
id iium-64734
recordtype eprints
spelling iium-647342018-07-10T04:24:43Z http://irep.iium.edu.my/64734/ Non-contact capacitive technique for biomass flow sensing Tasnim, Rumana Khan, Sheroz Arshad, Atika Hussein, Molla Rashied TK Electrical engineering. Electronics Nuclear engineering To facilitate real-time flow measurement, this paper aims to realize biomass flow sensing through electronic non-contact capacitive means. Hardware implementation has been carried out using a modified OP-AMP-based bridge circuit, with one arm made of a standard capacitance while the other arm is made from two specifically designed capacitive electrodes fitted on a piping system sensing biomass flow. The experimental results are targeted to obtain data for given biomass types through a custom-developed biomass flow piping system. Several flow affecting parameters namely: electrodes’ shapes, the location of electrodes on the piping system, biomass material type, and particle size have been considered in obtaining experimental data. Also, the circuit has been simulated to analyze flow sensing behavior for the proposed technique by evaluating the measurement data and assessing conformity between experimentally obtained and simulated data. Institute of Advanced Engineering and Science 2018-08 Article PeerReviewed application/pdf en http://irep.iium.edu.my/64734/1/64734_Non-Contact%20Capacitive%20Technique.pdf application/pdf en http://irep.iium.edu.my/64734/2/64734_Non-Contact%20Capacitive%20Technique_SCOPUS.pdf Tasnim, Rumana and Khan, Sheroz and Arshad, Atika and Hussein, Molla Rashied (2018) Non-contact capacitive technique for biomass flow sensing. Indonesian Journal of Electrical Engineering and Computer Science, 11 (2). pp. 531-541. ISSN 2502-4752 http://www.iaescore.com/journals/index.php/IJEECS/article/view/12644/8822 10.11591/ijeecs.v11.i2.pp531-541
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Tasnim, Rumana
Khan, Sheroz
Arshad, Atika
Hussein, Molla Rashied
Non-contact capacitive technique for biomass flow sensing
description To facilitate real-time flow measurement, this paper aims to realize biomass flow sensing through electronic non-contact capacitive means. Hardware implementation has been carried out using a modified OP-AMP-based bridge circuit, with one arm made of a standard capacitance while the other arm is made from two specifically designed capacitive electrodes fitted on a piping system sensing biomass flow. The experimental results are targeted to obtain data for given biomass types through a custom-developed biomass flow piping system. Several flow affecting parameters namely: electrodes’ shapes, the location of electrodes on the piping system, biomass material type, and particle size have been considered in obtaining experimental data. Also, the circuit has been simulated to analyze flow sensing behavior for the proposed technique by evaluating the measurement data and assessing conformity between experimentally obtained and simulated data.
format Article
author Tasnim, Rumana
Khan, Sheroz
Arshad, Atika
Hussein, Molla Rashied
author_facet Tasnim, Rumana
Khan, Sheroz
Arshad, Atika
Hussein, Molla Rashied
author_sort Tasnim, Rumana
title Non-contact capacitive technique for biomass flow sensing
title_short Non-contact capacitive technique for biomass flow sensing
title_full Non-contact capacitive technique for biomass flow sensing
title_fullStr Non-contact capacitive technique for biomass flow sensing
title_full_unstemmed Non-contact capacitive technique for biomass flow sensing
title_sort non-contact capacitive technique for biomass flow sensing
publisher Institute of Advanced Engineering and Science
publishDate 2018
url http://irep.iium.edu.my/64734/
http://irep.iium.edu.my/64734/
http://irep.iium.edu.my/64734/
http://irep.iium.edu.my/64734/1/64734_Non-Contact%20Capacitive%20Technique.pdf
http://irep.iium.edu.my/64734/2/64734_Non-Contact%20Capacitive%20Technique_SCOPUS.pdf
first_indexed 2023-09-18T21:31:52Z
last_indexed 2023-09-18T21:31:52Z
_version_ 1777412564175552512