General analysis of resonance coupled wireless power transfer (WPT) using inductive coils
In this paper, parameter analysis of the inductive coils is evaluated for low power Wireless Power Transfer (WPT) applications. Inductive coils are the major element used in the WPT systems, in which different shaped coils are employed. The selection of coils is very critical, depends purely on the...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English English English |
Published: |
Strojarski Facultet
2018
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/64627/ http://irep.iium.edu.my/64627/ http://irep.iium.edu.my/64627/ http://irep.iium.edu.my/64627/7/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer.pdf http://irep.iium.edu.my/64627/8/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer%20SCOPUS.pdf http://irep.iium.edu.my/64627/19/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer%20%28WPT%29%20using%20inductive%20coils_wos.pdf |
id |
iium-64627 |
---|---|
recordtype |
eprints |
spelling |
iium-646272019-01-24T04:14:07Z http://irep.iium.edu.my/64627/ General analysis of resonance coupled wireless power transfer (WPT) using inductive coils Nataraj, Chandrasekharan Khan, Sheroz Habaebi, Mohamed Hadi Muthalif, Asan G. A. TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices In this paper, parameter analysis of the inductive coils is evaluated for low power Wireless Power Transfer (WPT) applications. Inductive coils are the major element used in the WPT systems, in which different shaped coils are employed. The selection of coils is very critical, depends purely on the fundamental characteristics (shape and geometry) of the coils. In order to design a better system, three different shapes of coils, namely, circular, square and rectangular are designed and analysed. The vital parameters such as self-inductance, mutual inductance, quality factor, magnetic field and efficiency are evaluated for all three coils. It is observed that these parameters are maximal for circular as compared to the other two shapes. The circular coils produce higher voltage efficiency of 29% as compared to rectangular (25%) and square (23%) shaped coils. Thus, this paves a way to other researchers to suitably select circular inductive coils for wireless electricity applications. Strojarski Facultet 2018-06 Article PeerReviewed application/pdf en http://irep.iium.edu.my/64627/7/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer.pdf application/pdf en http://irep.iium.edu.my/64627/8/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer%20SCOPUS.pdf application/pdf en http://irep.iium.edu.my/64627/19/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer%20%28WPT%29%20using%20inductive%20coils_wos.pdf Nataraj, Chandrasekharan and Khan, Sheroz and Habaebi, Mohamed Hadi and Muthalif, Asan G. A. (2018) General analysis of resonance coupled wireless power transfer (WPT) using inductive coils. Technical Gazette=Tehnicki Vjesnik, 25 (3). pp. 720-726. ISSN 1330-3651 E-ISSN 1848-6339 https://hrcak.srce.hr/index.php?show=clanak&id_clanak_jezik=298240 https://doi.org/10.17559/TV-20160105041434 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English English |
topic |
TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices |
spellingShingle |
TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Nataraj, Chandrasekharan Khan, Sheroz Habaebi, Mohamed Hadi Muthalif, Asan G. A. General analysis of resonance coupled wireless power transfer (WPT) using inductive coils |
description |
In this paper, parameter analysis of the inductive coils is evaluated for low power Wireless Power Transfer (WPT) applications. Inductive coils are the major
element used in the WPT systems, in which different shaped coils are employed. The selection of coils is very critical, depends purely on the fundamental characteristics
(shape and geometry) of the coils. In order to design a better system, three different shapes of coils, namely, circular, square and rectangular are designed and analysed.
The vital parameters such as self-inductance, mutual inductance, quality factor, magnetic field and efficiency are evaluated for all three coils. It is observed that these
parameters are maximal for circular as compared to the other two shapes. The circular coils produce higher voltage efficiency of 29% as compared to rectangular (25%)
and square (23%) shaped coils. Thus, this paves a way to other researchers to suitably select circular inductive coils for wireless electricity applications. |
format |
Article |
author |
Nataraj, Chandrasekharan Khan, Sheroz Habaebi, Mohamed Hadi Muthalif, Asan G. A. |
author_facet |
Nataraj, Chandrasekharan Khan, Sheroz Habaebi, Mohamed Hadi Muthalif, Asan G. A. |
author_sort |
Nataraj, Chandrasekharan |
title |
General analysis of resonance coupled wireless power transfer (WPT) using inductive coils |
title_short |
General analysis of resonance coupled wireless power transfer (WPT) using inductive coils |
title_full |
General analysis of resonance coupled wireless power transfer (WPT) using inductive coils |
title_fullStr |
General analysis of resonance coupled wireless power transfer (WPT) using inductive coils |
title_full_unstemmed |
General analysis of resonance coupled wireless power transfer (WPT) using inductive coils |
title_sort |
general analysis of resonance coupled wireless power transfer (wpt) using inductive coils |
publisher |
Strojarski Facultet |
publishDate |
2018 |
url |
http://irep.iium.edu.my/64627/ http://irep.iium.edu.my/64627/ http://irep.iium.edu.my/64627/ http://irep.iium.edu.my/64627/7/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer.pdf http://irep.iium.edu.my/64627/8/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer%20SCOPUS.pdf http://irep.iium.edu.my/64627/19/64627%20General%20analysis%20of%20resonance%20coupled%20wireless%20power%20transfer%20%28WPT%29%20using%20inductive%20coils_wos.pdf |
first_indexed |
2023-09-18T21:31:43Z |
last_indexed |
2023-09-18T21:31:43Z |
_version_ |
1777412555182964736 |