Measurement of a wide-range of X-ray doses using specialty doped silica fibres
Using six types of tailor-made doped optical fibres, we carry out thermoluminescent (TL) studies of X-rays, investigating the TL yield for doses from 20 mGy through to 50 Gy. Dosimetric parameters were investigated for nominal 8 wt% Ge doped fibres that in two cases were co-doped, using B in one cas...
Main Authors: | , , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English English English |
Published: |
Elsevier Ltd
2017
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/62967/ http://irep.iium.edu.my/62967/ http://irep.iium.edu.my/62967/ http://irep.iium.edu.my/62967/13/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses_article.pdf http://irep.iium.edu.my/62967/2/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses%20_scopus.pdf http://irep.iium.edu.my/62967/14/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses_wos.pdf |
id |
iium-62967 |
---|---|
recordtype |
eprints |
spelling |
iium-629672019-08-22T02:16:16Z http://irep.iium.edu.my/62967/ Measurement of a wide-range of X-ray doses using specialty doped silica fibres Abdul San, Siti Fairus Hammond, R. Jafari, Shakardokht M. Wahab, Norfadira Amouzad Mahdiraji, Ghafour Ahmad Shaharuddin, Siti Shafiqah Abdul-Rashid, H. A. Maah, M. J. Aldousari, H. Alkhorayef,, Mohammed A. Alzimami, M. Bradley, David A. Q Science (General) RC Internal medicine Using six types of tailor-made doped optical fibres, we carry out thermoluminescent (TL) studies of X-rays, investigating the TL yield for doses from 20 mGy through to 50 Gy. Dosimetric parameters were investigated for nominal 8 wt% Ge doped fibres that in two cases were co-doped, using B in one case and Br in the other. A comparative measurement of surface analysis has also been made for non-annealed and annealed capillary fibres, use being made of X-ray Photoelectron Spectroscopy (XPS) analysis. Comparison was made with the conventional TL phosphor LiF in the form of the proprietary product TLD-100, including dose response and glow curves investigated for X-rays generated at 60 kVp over a dose range from 2 cGy to 50 Gy. The energy response of the fibres was also performed for X-rays generated at peak accelerating potentials of 80 kVp, 140 kVp, 250 kVp and 6 MV photons for an absorbed dose of 2 Gy. Present results show the samples to be suitable for use as TL dosimeters, with good linearity of response and a simple glow curve (simple trap) distribution. It has been established that the TL performance of an irradiated fibre is not only influenced by radiation parameters such as energy, dose-rate and total dose but also the type of fibre. Elsevier Ltd 2017-08 Article PeerReviewed application/pdf en http://irep.iium.edu.my/62967/13/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses_article.pdf application/pdf en http://irep.iium.edu.my/62967/2/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses%20_scopus.pdf application/pdf en http://irep.iium.edu.my/62967/14/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses_wos.pdf Abdul San, Siti Fairus and Hammond, R. and Jafari, Shakardokht M. and Wahab, Norfadira and Amouzad Mahdiraji, Ghafour and Ahmad Shaharuddin, Siti Shafiqah and Abdul-Rashid, H. A. and Maah, M. J. and Aldousari, H. and Alkhorayef,, Mohammed A. and Alzimami, M. and Bradley, David A. (2017) Measurement of a wide-range of X-ray doses using specialty doped silica fibres. Radiation Physics and Chemistry, 137. pp. 49-55. ISSN 0969-806X https://www.sciencedirect.com/science/article/pii/S0969806X16300834?via%3Dihub#! 10.1016/j.radphyschem.2016.03.008 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English English |
topic |
Q Science (General) RC Internal medicine |
spellingShingle |
Q Science (General) RC Internal medicine Abdul San, Siti Fairus Hammond, R. Jafari, Shakardokht M. Wahab, Norfadira Amouzad Mahdiraji, Ghafour Ahmad Shaharuddin, Siti Shafiqah Abdul-Rashid, H. A. Maah, M. J. Aldousari, H. Alkhorayef,, Mohammed A. Alzimami, M. Bradley, David A. Measurement of a wide-range of X-ray doses using specialty doped silica fibres |
description |
Using six types of tailor-made doped optical fibres, we carry out thermoluminescent (TL) studies of X-rays, investigating the TL yield for doses from 20 mGy through to 50 Gy. Dosimetric parameters were investigated for nominal 8 wt% Ge doped fibres that in two cases were co-doped, using B in one case and Br in the other. A comparative measurement of surface analysis has also been made for non-annealed and annealed capillary fibres, use being made of X-ray Photoelectron Spectroscopy (XPS) analysis. Comparison was made with the conventional TL phosphor LiF in the form of the proprietary product TLD-100, including dose response and glow curves investigated for X-rays generated at 60 kVp over a dose range from 2 cGy to 50 Gy. The energy response of the fibres was also performed for X-rays generated at peak accelerating potentials of 80 kVp, 140 kVp, 250 kVp and 6 MV photons for an absorbed dose of 2 Gy. Present results show the samples to be suitable for use as TL dosimeters, with good linearity of response and a simple glow curve (simple trap) distribution. It has been established that the TL performance of an irradiated fibre is not only influenced by radiation parameters such as energy, dose-rate and total dose but also the type of fibre. |
format |
Article |
author |
Abdul San, Siti Fairus Hammond, R. Jafari, Shakardokht M. Wahab, Norfadira Amouzad Mahdiraji, Ghafour Ahmad Shaharuddin, Siti Shafiqah Abdul-Rashid, H. A. Maah, M. J. Aldousari, H. Alkhorayef,, Mohammed A. Alzimami, M. Bradley, David A. |
author_facet |
Abdul San, Siti Fairus Hammond, R. Jafari, Shakardokht M. Wahab, Norfadira Amouzad Mahdiraji, Ghafour Ahmad Shaharuddin, Siti Shafiqah Abdul-Rashid, H. A. Maah, M. J. Aldousari, H. Alkhorayef,, Mohammed A. Alzimami, M. Bradley, David A. |
author_sort |
Abdul San, Siti Fairus |
title |
Measurement of a wide-range of X-ray doses using specialty doped silica fibres |
title_short |
Measurement of a wide-range of X-ray doses using specialty doped silica fibres |
title_full |
Measurement of a wide-range of X-ray doses using specialty doped silica fibres |
title_fullStr |
Measurement of a wide-range of X-ray doses using specialty doped silica fibres |
title_full_unstemmed |
Measurement of a wide-range of X-ray doses using specialty doped silica fibres |
title_sort |
measurement of a wide-range of x-ray doses using specialty doped silica fibres |
publisher |
Elsevier Ltd |
publishDate |
2017 |
url |
http://irep.iium.edu.my/62967/ http://irep.iium.edu.my/62967/ http://irep.iium.edu.my/62967/ http://irep.iium.edu.my/62967/13/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses_article.pdf http://irep.iium.edu.my/62967/2/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses%20_scopus.pdf http://irep.iium.edu.my/62967/14/62967_Measurement%20of%20a%20wide-range%20of%20X-ray%20doses_wos.pdf |
first_indexed |
2023-09-18T21:29:15Z |
last_indexed |
2023-09-18T21:29:15Z |
_version_ |
1777412399530246144 |