Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus

Long-term fetal heart rate (FHR) monitoring is necessary to ensure that any FHR abnormality, which may appear at any time during pregnancy and labor, can be detected. An ambulatory electrocardiogram (ECG) recorder employing three abdominal surface electrodes has been developed towards achieving such...

Full description

Bibliographic Details
Main Author: Ibrahimy, Muhammad Ibn
Format: Article
Language:English
Published: Zes Rokman Resources 2018
Subjects:
Online Access:http://irep.iium.edu.my/61415/
http://irep.iium.edu.my/61415/
http://irep.iium.edu.my/61415/1/IJCWED3_97.pdf
id iium-61415
recordtype eprints
spelling iium-614152018-01-26T08:45:59Z http://irep.iium.edu.my/61415/ Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus Ibrahimy, Muhammad Ibn T Technology (General) Long-term fetal heart rate (FHR) monitoring is necessary to ensure that any FHR abnormality, which may appear at any time during pregnancy and labor, can be detected. An ambulatory electrocardiogram (ECG) recorder employing three abdominal surface electrodes has been developed towards achieving such a monitoring. The difficulties encountered in determining the FHR from the maternal abdominal signal are mainly the interference due to the electromyogram and motion artifact, and relatively small amplitude of the fetal ECG compared to that of the maternal. Thus improvement to existing abdominal signal processing algorithm is necessary to increase the percentage of successful monitoring. A real-time algorithm has been developed for the simultaneous measurement of the fetal and maternal heart rates from the abdominal signal. The algorithm is based on digital filtering, adaptive thresholding, statistical properties in the time domain, and differencing of local maxima and minima. A filtering technique has been utilized in the proposed algorithm to extract the fetal signal from the maternal abdominal signal. This is an alternative to a previous method which subtracts the maternal complexes from the abdominal signal with a need to overcome the problem of matching a template to the complexes. The proposed algorithm is capable of continuous ambulatory FHR monitoring either off-line, by using recorded signals, or on-line by a clinician during antenatal examination. The performance of the algorithm has been evaluated of the heart rates tracing processed from the abdominal signals. The resulting average accuracy is 83% for the FHR detection. The detection of the FHR from the maternal abdominal signal by the developed algorithm has also been compared with a short-term monitoring commercial instrument IFM-500 for the assessment of the reliability of the algorithm. The performance achieved from the comparison shows non-significant differences of means, low error percentages and linear correlation coefficient. A portable system based on the developed algorithm has the potential for increased percentage of real-time FHR detection thus enabling successful long-term fetal monitoring. Zes Rokman Resources 2018 Article PeerReviewed application/pdf en http://irep.iium.edu.my/61415/1/IJCWED3_97.pdf Ibrahimy, Muhammad Ibn (2018) Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus. International Journal for Studies on Children, Women, Elderly and Disabled People, 3 (1). pp. 195-199. ISSN 0128-309X E-ISSN 0128-309X http://www.ijcwed.com/issue/international-journal-for-studies-on-children-women-elderly-and-disabled-vol-3-january-2018/
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic T Technology (General)
spellingShingle T Technology (General)
Ibrahimy, Muhammad Ibn
Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
description Long-term fetal heart rate (FHR) monitoring is necessary to ensure that any FHR abnormality, which may appear at any time during pregnancy and labor, can be detected. An ambulatory electrocardiogram (ECG) recorder employing three abdominal surface electrodes has been developed towards achieving such a monitoring. The difficulties encountered in determining the FHR from the maternal abdominal signal are mainly the interference due to the electromyogram and motion artifact, and relatively small amplitude of the fetal ECG compared to that of the maternal. Thus improvement to existing abdominal signal processing algorithm is necessary to increase the percentage of successful monitoring. A real-time algorithm has been developed for the simultaneous measurement of the fetal and maternal heart rates from the abdominal signal. The algorithm is based on digital filtering, adaptive thresholding, statistical properties in the time domain, and differencing of local maxima and minima. A filtering technique has been utilized in the proposed algorithm to extract the fetal signal from the maternal abdominal signal. This is an alternative to a previous method which subtracts the maternal complexes from the abdominal signal with a need to overcome the problem of matching a template to the complexes. The proposed algorithm is capable of continuous ambulatory FHR monitoring either off-line, by using recorded signals, or on-line by a clinician during antenatal examination. The performance of the algorithm has been evaluated of the heart rates tracing processed from the abdominal signals. The resulting average accuracy is 83% for the FHR detection. The detection of the FHR from the maternal abdominal signal by the developed algorithm has also been compared with a short-term monitoring commercial instrument IFM-500 for the assessment of the reliability of the algorithm. The performance achieved from the comparison shows non-significant differences of means, low error percentages and linear correlation coefficient. A portable system based on the developed algorithm has the potential for increased percentage of real-time FHR detection thus enabling successful long-term fetal monitoring.
format Article
author Ibrahimy, Muhammad Ibn
author_facet Ibrahimy, Muhammad Ibn
author_sort Ibrahimy, Muhammad Ibn
title Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
title_short Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
title_full Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
title_fullStr Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
title_full_unstemmed Fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
title_sort fetal heart rate monitoring during pregnancy for assessing the well being of the fetus
publisher Zes Rokman Resources
publishDate 2018
url http://irep.iium.edu.my/61415/
http://irep.iium.edu.my/61415/
http://irep.iium.edu.my/61415/1/IJCWED3_97.pdf
first_indexed 2023-09-18T21:27:07Z
last_indexed 2023-09-18T21:27:07Z
_version_ 1777412265445687296