A modified laboratory approach to determine reaeration rate for river water

It is reported that reaeration rates determined from laboratory investigation may not suit well in predicting reaeration rate of natural streams. Sampling method during reaeration experiment is a potential source of error in laboratory estimation of reaeration rate coefficient for river waters,...

Full description

Bibliographic Details
Main Authors: ., Md Nuruzzaman, Al-Mamun, Abdullah, Salleh, Md Noor
Format: Article
Language:English
English
English
English
Published: Springer Berlin Heidelberg 2018
Subjects:
Online Access:http://irep.iium.edu.my/59537/
http://irep.iium.edu.my/59537/
http://irep.iium.edu.my/59537/
http://irep.iium.edu.my/59537/1/Online%20version%20of%20Paper.pdf
http://irep.iium.edu.my/59537/7/59537_A%20modified%20laboratory%20approach%20to%20determine%20reaeration_article.pdf
http://irep.iium.edu.my/59537/8/59537_A%20modified%20laboratory%20approach%20to%20determine%20reaeration_scopus.pdf
http://irep.iium.edu.my/59537/19/59537_A%20Modified%20Laboratory%20Approach%20to%20Determine%20Reaeration%20Rate%20for%20River%20Water_WOS.pdf
id iium-59537
recordtype eprints
spelling iium-595372019-01-24T01:33:19Z http://irep.iium.edu.my/59537/ A modified laboratory approach to determine reaeration rate for river water ., Md Nuruzzaman Al-Mamun, Abdullah Salleh, Md Noor TD Environmental technology. Sanitary engineering TD172 Environmental pollution It is reported that reaeration rates determined from laboratory investigation may not suit well in predicting reaeration rate of natural streams. Sampling method during reaeration experiment is a potential source of error in laboratory estimation of reaeration rate coefficient for river waters, which has been addressed in this research. A modified method based on sampling procedure in a flume was adopted to develop a reaeration rate equation for Pusu River in Malaysia,which is demographically a very important river. An important feature including several culverts along the course of the river was also considered to model dissolved oxygen (DO) concentration.DOwas calibrated and validated using water quality analysis simulation program (WASP) considering appropriate kinetic rate coefficients for Pusu River. Performance of the new reaeration rate equation and other process equations in the calibration and validation data was assessed in terms of root-mean-square error (RMSE), mean error between observed and predicted data and R2 value. Study results revealed that the equation developed in B Abdullah Al-Mamun mamun@iium.edu.my Md Nuruzzaman suvo.ruet@gmail.com http://waterzaman.weebly.com/ Md Noor Bin Salleh mdnoor@iium.edu.my 1 Department of Civil Engineering, Rangpur Engineering College, Rangpur 5403, Bangladesh 2 Department of Civil Engineering, Kulliyyah of Engineering, International Islamic University Malaysia (IIUM), 53100 Kuala Lumpur, Malaysia 3 Bioenvironmental Engineering Research Center (BERC), Kulliyyah of Engineering, International Islamic University Malaysia (IIUM), 53100 Kuala Lumpur, Malaysia this research considering the impact of culverts on reaeration rate predicted DO in Pusu River with improved accuracy as compared to the other equations. RMSEs were found to be 0.083 and 0.067 mg/L for calibration and validation data, respectively. Mean errors of observed and model-predicted data were 0.06 and 0.05 mg/L for calibration and validation,respectively. The R2 value was 0.99 in both cases. The study results facilitate accuracy in future studies on DO of Pusu River. Springer Berlin Heidelberg 2018-04-01 Article PeerReviewed application/pdf en http://irep.iium.edu.my/59537/1/Online%20version%20of%20Paper.pdf application/pdf en http://irep.iium.edu.my/59537/7/59537_A%20modified%20laboratory%20approach%20to%20determine%20reaeration_article.pdf application/pdf en http://irep.iium.edu.my/59537/8/59537_A%20modified%20laboratory%20approach%20to%20determine%20reaeration_scopus.pdf application/pdf en http://irep.iium.edu.my/59537/19/59537_A%20Modified%20Laboratory%20Approach%20to%20Determine%20Reaeration%20Rate%20for%20River%20Water_WOS.pdf ., Md Nuruzzaman and Al-Mamun, Abdullah and Salleh, Md Noor (2018) A modified laboratory approach to determine reaeration rate for river water. Arabian Journal for Science and Engineering, 43 (4). pp. 2037-2051. ISSN 1319-8025 E-ISSN 2191-4281 (In Press) https://link.springer.com/article/10.1007/s13369-017-2897-0 10.1007/s13369-017-2897-0
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
English
English
topic TD Environmental technology. Sanitary engineering
TD172 Environmental pollution
spellingShingle TD Environmental technology. Sanitary engineering
TD172 Environmental pollution
., Md Nuruzzaman
Al-Mamun, Abdullah
Salleh, Md Noor
A modified laboratory approach to determine reaeration rate for river water
description It is reported that reaeration rates determined from laboratory investigation may not suit well in predicting reaeration rate of natural streams. Sampling method during reaeration experiment is a potential source of error in laboratory estimation of reaeration rate coefficient for river waters, which has been addressed in this research. A modified method based on sampling procedure in a flume was adopted to develop a reaeration rate equation for Pusu River in Malaysia,which is demographically a very important river. An important feature including several culverts along the course of the river was also considered to model dissolved oxygen (DO) concentration.DOwas calibrated and validated using water quality analysis simulation program (WASP) considering appropriate kinetic rate coefficients for Pusu River. Performance of the new reaeration rate equation and other process equations in the calibration and validation data was assessed in terms of root-mean-square error (RMSE), mean error between observed and predicted data and R2 value. Study results revealed that the equation developed in B Abdullah Al-Mamun mamun@iium.edu.my Md Nuruzzaman suvo.ruet@gmail.com http://waterzaman.weebly.com/ Md Noor Bin Salleh mdnoor@iium.edu.my 1 Department of Civil Engineering, Rangpur Engineering College, Rangpur 5403, Bangladesh 2 Department of Civil Engineering, Kulliyyah of Engineering, International Islamic University Malaysia (IIUM), 53100 Kuala Lumpur, Malaysia 3 Bioenvironmental Engineering Research Center (BERC), Kulliyyah of Engineering, International Islamic University Malaysia (IIUM), 53100 Kuala Lumpur, Malaysia this research considering the impact of culverts on reaeration rate predicted DO in Pusu River with improved accuracy as compared to the other equations. RMSEs were found to be 0.083 and 0.067 mg/L for calibration and validation data, respectively. Mean errors of observed and model-predicted data were 0.06 and 0.05 mg/L for calibration and validation,respectively. The R2 value was 0.99 in both cases. The study results facilitate accuracy in future studies on DO of Pusu River.
format Article
author ., Md Nuruzzaman
Al-Mamun, Abdullah
Salleh, Md Noor
author_facet ., Md Nuruzzaman
Al-Mamun, Abdullah
Salleh, Md Noor
author_sort ., Md Nuruzzaman
title A modified laboratory approach to determine reaeration rate for river water
title_short A modified laboratory approach to determine reaeration rate for river water
title_full A modified laboratory approach to determine reaeration rate for river water
title_fullStr A modified laboratory approach to determine reaeration rate for river water
title_full_unstemmed A modified laboratory approach to determine reaeration rate for river water
title_sort modified laboratory approach to determine reaeration rate for river water
publisher Springer Berlin Heidelberg
publishDate 2018
url http://irep.iium.edu.my/59537/
http://irep.iium.edu.my/59537/
http://irep.iium.edu.my/59537/
http://irep.iium.edu.my/59537/1/Online%20version%20of%20Paper.pdf
http://irep.iium.edu.my/59537/7/59537_A%20modified%20laboratory%20approach%20to%20determine%20reaeration_article.pdf
http://irep.iium.edu.my/59537/8/59537_A%20modified%20laboratory%20approach%20to%20determine%20reaeration_scopus.pdf
http://irep.iium.edu.my/59537/19/59537_A%20Modified%20Laboratory%20Approach%20to%20Determine%20Reaeration%20Rate%20for%20River%20Water_WOS.pdf
first_indexed 2023-09-18T21:24:21Z
last_indexed 2023-09-18T21:24:21Z
_version_ 1777412091906359296