Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems

In recent years, the utility grid system is more essential for the power transmission and distribution system because it cannot produce harmful gases or no discharge waste in the environment. PWM based phase synchronous invert systems are generally utilized in the high efficiency energy supply, long...

Full description

Bibliographic Details
Main Authors: Raham, Tawfik, Ibrahimy, Muhammad Ibn, Motakabber, S. M. A.
Format: Conference or Workshop Item
Language:English
Published: 2016
Subjects:
Online Access:http://irep.iium.edu.my/54245/
http://irep.iium.edu.my/54245/
http://irep.iium.edu.my/54245/18/54245_Synchronization%20of%20Output%20Voltage_complete.pdf
id iium-54245
recordtype eprints
spelling iium-542452017-11-17T01:47:00Z http://irep.iium.edu.my/54245/ Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems Raham, Tawfik Ibrahimy, Muhammad Ibn Motakabber, S. M. A. T Technology (General) In recent years, the utility grid system is more essential for the power transmission and distribution system because it cannot produce harmful gases or no discharge waste in the environment. PWM based phase synchronous invert systems are generally utilized in the high efficiency energy supply, long distance and higher power quality. The inverter output voltage depends on the coupling transformer, input sources and invert controllers. An inverter using a three leg IGBT has been designed for utility grid and simulated by using MATLAB2014a. In this paper, both sides of the LCL filters are used for removing the DC ripple current, reducing the noise and synchronous the output phase between inverter and the utility grid. The PWM controller has created pulse signal to control the inverter, electronic switches and precisely synchronize with grid line frequency. This system, the input DC voltage 500V, switching frequency 1.65 kHz, grid frequency 50Hz, 20 km feeder (resistance, inductance and capacitance per unit length, which are 0.1153, 1.05e-3 and 11.33e-09 ohms/km) with 30MW three phase load (active and inductive reactive power which are 30e6 W and 2e6 var) and also a balanced utility grid load of star configuration (00, 1200, and 2400 degree) are considered in the design. On the other hand, three phase transformer consists of three signal phase transformers, normal power 100e3, magnetization resistance and inductance which are 500 pu and 416.67pu are considered in this design. The system conversion efficiency is 99.94% and 99.96%, while the total THD are 0.06% on inverter side and 0.04% on grid side. 2016 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/54245/18/54245_Synchronization%20of%20Output%20Voltage_complete.pdf Raham, Tawfik and Ibrahimy, Muhammad Ibn and Motakabber, S. M. A. (2016) Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems. In: 3rd International Conference on Science and Social Research (CSSR 2016), 6th-7th December 2016, Putrajaya, Malaysia. (Unpublished) http://cssr.uitm.edu.my/2016/
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic T Technology (General)
spellingShingle T Technology (General)
Raham, Tawfik
Ibrahimy, Muhammad Ibn
Motakabber, S. M. A.
Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
description In recent years, the utility grid system is more essential for the power transmission and distribution system because it cannot produce harmful gases or no discharge waste in the environment. PWM based phase synchronous invert systems are generally utilized in the high efficiency energy supply, long distance and higher power quality. The inverter output voltage depends on the coupling transformer, input sources and invert controllers. An inverter using a three leg IGBT has been designed for utility grid and simulated by using MATLAB2014a. In this paper, both sides of the LCL filters are used for removing the DC ripple current, reducing the noise and synchronous the output phase between inverter and the utility grid. The PWM controller has created pulse signal to control the inverter, electronic switches and precisely synchronize with grid line frequency. This system, the input DC voltage 500V, switching frequency 1.65 kHz, grid frequency 50Hz, 20 km feeder (resistance, inductance and capacitance per unit length, which are 0.1153, 1.05e-3 and 11.33e-09 ohms/km) with 30MW three phase load (active and inductive reactive power which are 30e6 W and 2e6 var) and also a balanced utility grid load of star configuration (00, 1200, and 2400 degree) are considered in the design. On the other hand, three phase transformer consists of three signal phase transformers, normal power 100e3, magnetization resistance and inductance which are 500 pu and 416.67pu are considered in this design. The system conversion efficiency is 99.94% and 99.96%, while the total THD are 0.06% on inverter side and 0.04% on grid side.
format Conference or Workshop Item
author Raham, Tawfik
Ibrahimy, Muhammad Ibn
Motakabber, S. M. A.
author_facet Raham, Tawfik
Ibrahimy, Muhammad Ibn
Motakabber, S. M. A.
author_sort Raham, Tawfik
title Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
title_short Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
title_full Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
title_fullStr Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
title_full_unstemmed Synchronization of output voltage waveforms in phase synchronous inverter with LCL filter for smart grid systems
title_sort synchronization of output voltage waveforms in phase synchronous inverter with lcl filter for smart grid systems
publishDate 2016
url http://irep.iium.edu.my/54245/
http://irep.iium.edu.my/54245/
http://irep.iium.edu.my/54245/18/54245_Synchronization%20of%20Output%20Voltage_complete.pdf
first_indexed 2023-09-18T21:16:45Z
last_indexed 2023-09-18T21:16:45Z
_version_ 1777411613634068480