Portable thumb training system for EMG signal measurement and analysis

Restoring human limb that is lost due to accidents or amputation because of vascular diseases with prosthesis is one challenging issue in engineering field. The loss of human body, especially the upper and lower limbs will limit the daily activities of patient in many ways. There were many studi...

Full description

Bibliographic Details
Main Authors: Roslan, Muhammad Rozaidi, Sidek, Shahrul Naim, Toha @ Tohara, Siti Fauziah, Sidek, Sabrilhakim, Mohd Khalid, Mohd Shukry
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2016
Subjects:
Online Access:http://irep.iium.edu.my/53958/
http://irep.iium.edu.my/53958/
http://irep.iium.edu.my/53958/
http://irep.iium.edu.my/53958/1/53958.pdf
http://irep.iium.edu.my/53958/2/53958-Portable%20Thumb%20Training%20System%20for%20EMG_SCOPUS.pdf
id iium-53958
recordtype eprints
spelling iium-539582019-01-10T04:56:45Z http://irep.iium.edu.my/53958/ Portable thumb training system for EMG signal measurement and analysis Roslan, Muhammad Rozaidi Sidek, Shahrul Naim Toha @ Tohara, Siti Fauziah Sidek, Sabrilhakim Mohd Khalid, Mohd Shukry T Technology (General) Restoring human limb that is lost due to accidents or amputation because of vascular diseases with prosthesis is one challenging issue in engineering field. The loss of human body, especially the upper and lower limbs will limit the daily activities of patient in many ways. There were many studies that had been done previously in developing prostheses which were simpler in the forms than human limb. However, the performance of these units was mostly unnatural and is damped by constraint in the model of the limbs. In this paper, the development of thumb training system that allows the measurement of electromyography (EMG) signal when the thumb is flexed at different angles with varying force is discussed. The parameters are then possible to be used with conjunction of Hill’s muscle model to develop a more precise model of the thumb. The platform also features several adjustments so as to suit various size of human hands. The result from EMG measurement from the system shows that the system is able to characterize the EMG signal of thumb at different pose and force. IEEE 2016 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/53958/1/53958.pdf application/pdf en http://irep.iium.edu.my/53958/2/53958-Portable%20Thumb%20Training%20System%20for%20EMG_SCOPUS.pdf Roslan, Muhammad Rozaidi and Sidek, Shahrul Naim and Toha @ Tohara, Siti Fauziah and Sidek, Sabrilhakim and Mohd Khalid, Mohd Shukry (2016) Portable thumb training system for EMG signal measurement and analysis. In: 6th International Conference on Computer and Communication Engineering (ICCCE 2016), 25th-27th July 2016, Kuala Lumpur. http://ieeexplore.ieee.org/document/7808302/ 10.1109/ICCCE.2016.44
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic T Technology (General)
spellingShingle T Technology (General)
Roslan, Muhammad Rozaidi
Sidek, Shahrul Naim
Toha @ Tohara, Siti Fauziah
Sidek, Sabrilhakim
Mohd Khalid, Mohd Shukry
Portable thumb training system for EMG signal measurement and analysis
description Restoring human limb that is lost due to accidents or amputation because of vascular diseases with prosthesis is one challenging issue in engineering field. The loss of human body, especially the upper and lower limbs will limit the daily activities of patient in many ways. There were many studies that had been done previously in developing prostheses which were simpler in the forms than human limb. However, the performance of these units was mostly unnatural and is damped by constraint in the model of the limbs. In this paper, the development of thumb training system that allows the measurement of electromyography (EMG) signal when the thumb is flexed at different angles with varying force is discussed. The parameters are then possible to be used with conjunction of Hill’s muscle model to develop a more precise model of the thumb. The platform also features several adjustments so as to suit various size of human hands. The result from EMG measurement from the system shows that the system is able to characterize the EMG signal of thumb at different pose and force.
format Conference or Workshop Item
author Roslan, Muhammad Rozaidi
Sidek, Shahrul Naim
Toha @ Tohara, Siti Fauziah
Sidek, Sabrilhakim
Mohd Khalid, Mohd Shukry
author_facet Roslan, Muhammad Rozaidi
Sidek, Shahrul Naim
Toha @ Tohara, Siti Fauziah
Sidek, Sabrilhakim
Mohd Khalid, Mohd Shukry
author_sort Roslan, Muhammad Rozaidi
title Portable thumb training system for EMG signal measurement and analysis
title_short Portable thumb training system for EMG signal measurement and analysis
title_full Portable thumb training system for EMG signal measurement and analysis
title_fullStr Portable thumb training system for EMG signal measurement and analysis
title_full_unstemmed Portable thumb training system for EMG signal measurement and analysis
title_sort portable thumb training system for emg signal measurement and analysis
publisher IEEE
publishDate 2016
url http://irep.iium.edu.my/53958/
http://irep.iium.edu.my/53958/
http://irep.iium.edu.my/53958/
http://irep.iium.edu.my/53958/1/53958.pdf
http://irep.iium.edu.my/53958/2/53958-Portable%20Thumb%20Training%20System%20for%20EMG_SCOPUS.pdf
first_indexed 2023-09-18T21:16:20Z
last_indexed 2023-09-18T21:16:20Z
_version_ 1777411587404988416