Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius
Introduction: A 3D model of the aqueduct of Sylvius, i.e. the region of interest (ROI) in the human ventricular system (HVS) is used to investigate the flow of CSF within the human brain, using Computational Fluid Dynamics (CFD). CSF can be modeled as a Newtonian Fluid and its flow through the ROI...
Main Authors: | , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2011
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/5187/ http://irep.iium.edu.my/5187/1/CSF_Flow_Analysis_for_CoR_2011.pdf |
id |
iium-5187 |
---|---|
recordtype |
eprints |
spelling |
iium-51872013-04-27T08:15:12Z http://irep.iium.edu.my/5187/ Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius H, Edi Azali A G, Ahmad Lutfi S, Amir Hamzah Osman, Kahar A K, Mohammed Rafiq Abd. Aziz, Azian Sa'at@Yusof, Azlin TA164 Bioengineering Introduction: A 3D model of the aqueduct of Sylvius, i.e. the region of interest (ROI) in the human ventricular system (HVS) is used to investigate the flow of CSF within the human brain, using Computational Fluid Dynamics (CFD). CSF can be modeled as a Newtonian Fluid and its flow through the ROI can be visualized using CFD. In this investigation a 3D geometric model of the ROI is constructed from MRI data. The flow of CSF within the ROI is a complicated phenomenon due to the complex ROI geometry. Different flow rate was simulated at the foramen of Monro and a small stenosis was modeled at the middle of the Aqueduct of Sylvius. Understanding the nature of CSF flow may allow engineers and physicians to design medical techniques and drugs to treat various ventricular complications, such as hydrocephalus as a result of obstruction. Objective: To analyze cerebrospinal fluid flow through the region of interest i.e.Aqueduct of Sylvius. Scopes: •With&withoutblockageinAqueductofSylvius. •Numericalstudy(3D-modelling). •Laminar and turbulence model is used. Conclusion: CFD simulations was used to obtain ventricular geometry from anatomical MRI images. In Engineering Fluid Dynamics (EFD), various flow rates was artificially defined at inlets & stenosed aqueduct was modeled within the domain of the geometry. The results show as the flow rate increase, the pressure drop of CSF in the ROI proportionally increased. For normal CSF flow rate, the presence of stenosis in the aqueduct demonstrates a significant increased pressure drop. 2011-04-08 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/5187/1/CSF_Flow_Analysis_for_CoR_2011.pdf H, Edi Azali and A G, Ahmad Lutfi and S, Amir Hamzah and Osman, Kahar and A K, Mohammed Rafiq and Abd. Aziz, Azian and Sa'at@Yusof, Azlin (2011) Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius. In: Annual Scientific Meeting, College of Radiology, Malaysia, 8 - 10 April 2011, The Legend Hotel, Kuala Lumpur. (Unpublished) |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
TA164 Bioengineering |
spellingShingle |
TA164 Bioengineering H, Edi Azali A G, Ahmad Lutfi S, Amir Hamzah Osman, Kahar A K, Mohammed Rafiq Abd. Aziz, Azian Sa'at@Yusof, Azlin Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius |
description |
Introduction:
A 3D model of the aqueduct of Sylvius, i.e. the region of interest (ROI) in the human ventricular system (HVS) is used to investigate the flow of CSF within the human brain, using Computational Fluid Dynamics (CFD). CSF can be modeled as a Newtonian Fluid and its flow through the ROI can be visualized using CFD.
In this investigation a 3D geometric model of the ROI is constructed from MRI data. The flow of CSF within the ROI is a complicated phenomenon due to the complex ROI geometry. Different flow rate was simulated at the foramen of Monro and a small stenosis was modeled at the middle of the Aqueduct of Sylvius. Understanding the nature of CSF flow may allow engineers and physicians to design medical techniques and drugs to treat various ventricular complications, such as hydrocephalus as a result of obstruction.
Objective:
To analyze cerebrospinal fluid flow through the region of interest i.e.Aqueduct of Sylvius.
Scopes:
•With&withoutblockageinAqueductofSylvius.
•Numericalstudy(3D-modelling).
•Laminar and turbulence model is used.
Conclusion:
CFD simulations was used to obtain ventricular geometry from anatomical MRI images. In Engineering Fluid Dynamics (EFD), various flow rates was artificially defined at inlets & stenosed aqueduct was modeled within the domain of the geometry. The results show as the flow rate increase, the pressure drop of CSF in the ROI proportionally increased. For normal CSF flow rate, the presence of stenosis in the aqueduct demonstrates a significant increased pressure drop. |
format |
Conference or Workshop Item |
author |
H, Edi Azali A G, Ahmad Lutfi S, Amir Hamzah Osman, Kahar A K, Mohammed Rafiq Abd. Aziz, Azian Sa'at@Yusof, Azlin |
author_facet |
H, Edi Azali A G, Ahmad Lutfi S, Amir Hamzah Osman, Kahar A K, Mohammed Rafiq Abd. Aziz, Azian Sa'at@Yusof, Azlin |
author_sort |
H, Edi Azali |
title |
Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius |
title_short |
Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius |
title_full |
Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius |
title_fullStr |
Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius |
title_full_unstemmed |
Analysis of the Cerebrospinal Fluid Flow in the Stenosed Aqueduct of Sylvius |
title_sort |
analysis of the cerebrospinal fluid flow in the stenosed aqueduct of sylvius |
publishDate |
2011 |
url |
http://irep.iium.edu.my/5187/ http://irep.iium.edu.my/5187/1/CSF_Flow_Analysis_for_CoR_2011.pdf |
first_indexed |
2023-09-18T20:13:40Z |
last_indexed |
2023-09-18T20:13:40Z |
_version_ |
1777407644326166528 |