The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results
INTRODUCTION: Bacterial infection during implant placement is a serious complication. The reason for this infection is mainly due to contamination during surgical implantation with the formation of a resistant biofilm at the implant surface. The infection risks may be overcome by application of or...
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
Malaysian Orthopaedic Association
2017
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/51639/ http://irep.iium.edu.my/51639/ http://irep.iium.edu.my/51639/1/51639_tentative.pdf http://irep.iium.edu.my/51639/2/51639_poster.pdf |
id |
iium-51639 |
---|---|
recordtype |
eprints |
spelling |
iium-516392017-08-07T08:59:12Z http://irep.iium.edu.my/51639/ The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results Mohd Jan, Nurul Hafiza Zulkifly, Ahmad Hafiz Ibrahim, Mohd Zulfadzli Shaban, Munirah RD701 Orthopedics INTRODUCTION: Bacterial infection during implant placement is a serious complication. The reason for this infection is mainly due to contamination during surgical implantation with the formation of a resistant biofilm at the implant surface. The infection risks may be overcome by application of orthopaedic metallic implant coated with 3% silver composite as alternative treatment of implant-infection related. The purpose of this study was to investigate the potential effect of test material against infection through in vitro and in vivo experimental settings. MATERIALS & METHODS: The antibacterial property of orthopaedic metal implants was investigated using Staphylococcus aureus ATCC 25923. The silver coated plate and non coated plate which served as control were placed on the surface of sterile agar media. The samples then were incubated with temperature 37ºC for 24 hours and continued incubated up to 48 hours for assessment. In this study, the antibacterial effect was evaluated based on the diameter of inhibition zone using in situ inhibitory test. As for pilot study through in vivo evaluation, the silver coated plate was surgically implanted at right tibia and non coated plate which served as control was implanted at left tibia of New Zealand White Rabbit after six hours of exposure at surgical site. The subject was observed daily for infection effect up to three weeks. Microbial analyze was performed after euthanasia for assessment day. No antibiotics were administered. Animal was sacrificed at 3 weeks and evaluated for infection through microbial assessments. RESULTS: The outcome of this study revealed positive response of the silver as antibacterial agent as illustrated in Figure 1 and Figure 2. Figure 1 show the inhabitation zone with diameter 5mm was noted after 48 hours of incubation at study plate (left side) on the agar media compared to control Figure 2 illustrates the culture assessment after 24 hours of incubation at 37°C. There are no colonies noted at study plate (coated plate) on the agar media compared to control. DISCUSSIONS: The outcome of this study revealed positive response of the silver as antibacterial agent. The study is still ongoing CONCLUSION: In conclusion, this result suggested that orthopaedic metal implant coated with silver composite has the intended potential as antibacterial and provide protection against medical device-related infection. Malaysian Orthopaedic Association 2017-05-19 Conference or Workshop Item NonPeerReviewed application/pdf en http://irep.iium.edu.my/51639/1/51639_tentative.pdf application/pdf en http://irep.iium.edu.my/51639/2/51639_poster.pdf Mohd Jan, Nurul Hafiza and Zulkifly, Ahmad Hafiz and Ibrahim, Mohd Zulfadzli and Shaban, Munirah (2017) The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results. In: 50th Anniversary Golden Jubilee of Malaysian Orthopaedic Association & 47th Annual Scientific Meeting / Annual General Meeting 2017, 19th-21st May 2017, Kuala Lumpur, Malaysia. (Unpublished) http://moa-home.com/moa2017/files/MOA2017_SouvenirProgramme.pdf |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
RD701 Orthopedics |
spellingShingle |
RD701 Orthopedics Mohd Jan, Nurul Hafiza Zulkifly, Ahmad Hafiz Ibrahim, Mohd Zulfadzli Shaban, Munirah The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
description |
INTRODUCTION:
Bacterial infection during implant placement is a serious complication. The reason for this infection is mainly due to contamination during surgical implantation with the formation of a resistant biofilm at the implant surface. The infection risks may be overcome by application of orthopaedic metallic implant coated with 3% silver composite as alternative treatment of implant-infection related. The purpose of this study was to investigate the potential effect of test material against infection through in vitro and in vivo experimental settings.
MATERIALS & METHODS:
The antibacterial property of orthopaedic metal implants was investigated using Staphylococcus aureus ATCC 25923. The silver coated plate and non coated plate which served as control were placed on the surface of sterile agar media. The samples then were incubated with temperature 37ºC for 24 hours and continued incubated up to 48 hours for assessment. In this study, the antibacterial effect was evaluated based on the diameter of inhibition zone using in situ inhibitory test. As for pilot study through in vivo evaluation, the silver coated plate was surgically implanted at right tibia and non coated plate which served as control was implanted at left tibia of New Zealand White Rabbit after six hours of exposure at surgical site. The subject was observed daily for infection effect up to three weeks. Microbial analyze was performed after euthanasia for assessment day. No antibiotics were administered. Animal was sacrificed at 3 weeks and evaluated for infection through microbial assessments.
RESULTS:
The outcome of this study revealed positive response of the silver as antibacterial agent as illustrated in Figure 1 and Figure 2.
Figure 1 show the inhabitation zone with diameter 5mm was noted after 48 hours of incubation at study plate (left side) on the agar media compared to control
Figure 2 illustrates the culture assessment after 24 hours of incubation at 37°C. There are no colonies noted at study plate (coated plate) on the agar media compared to control.
DISCUSSIONS:
The outcome of this study revealed positive response of the silver as antibacterial agent. The study is still ongoing
CONCLUSION:
In conclusion, this result suggested that orthopaedic metal implant coated with silver composite has the intended potential as antibacterial and provide protection against medical device-related infection. |
format |
Conference or Workshop Item |
author |
Mohd Jan, Nurul Hafiza Zulkifly, Ahmad Hafiz Ibrahim, Mohd Zulfadzli Shaban, Munirah |
author_facet |
Mohd Jan, Nurul Hafiza Zulkifly, Ahmad Hafiz Ibrahim, Mohd Zulfadzli Shaban, Munirah |
author_sort |
Mohd Jan, Nurul Hafiza |
title |
The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
title_short |
The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
title_full |
The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
title_fullStr |
The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
title_full_unstemmed |
The early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
title_sort |
early outcome in antibacterial activity of orthopaedic metal implant coated with silver composite as future implant related infection treatment – preliminary results |
publisher |
Malaysian Orthopaedic Association |
publishDate |
2017 |
url |
http://irep.iium.edu.my/51639/ http://irep.iium.edu.my/51639/ http://irep.iium.edu.my/51639/1/51639_tentative.pdf http://irep.iium.edu.my/51639/2/51639_poster.pdf |
first_indexed |
2023-09-18T21:13:08Z |
last_indexed |
2023-09-18T21:13:08Z |
_version_ |
1777411385903284224 |