Poincare based PPG signal analysis for varying physiological states

This paper investigates the similarity and dissimilarity of the Photoplethysmography (PPG) signals depending upon the physiological conditions in non­linear domain. Current paper also illustrates the variations in PPG signal for volunteers of age group among 20's (twenties). Easy Pulse analyz...

Full description

Bibliographic Details
Main Authors: Kazmi , Syed Absar, Shah, Mansoor Hussain, Khan, Sheroz, Khalifa, Othman Omran, ., Muhammad Muzammil
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2016
Subjects:
Online Access:http://irep.iium.edu.my/50910/
http://irep.iium.edu.my/50910/
http://irep.iium.edu.my/50910/
http://irep.iium.edu.my/50910/4/50910.pdf
http://irep.iium.edu.my/50910/5/50910-Poincare_based_PPG_signal_analysis_for_varying_physiological_SCOPUS.pdf
id iium-50910
recordtype eprints
spelling iium-509102016-11-03T08:55:57Z http://irep.iium.edu.my/50910/ Poincare based PPG signal analysis for varying physiological states Kazmi , Syed Absar Shah, Mansoor Hussain Khan, Sheroz Khalifa, Othman Omran ., Muhammad Muzammil T10.5 Communication of technical information This paper investigates the similarity and dissimilarity of the Photoplethysmography (PPG) signals depending upon the physiological conditions in non­linear domain. Current paper also illustrates the variations in PPG signal for volunteers of age group among 20's (twenties). Easy Pulse analyzer Sensor module which operates on working principle of pulse oximetry which enables the photo sensing technique by detecting the infra­red light penetrating through the respective part of body in this case is index finger. Afterwards it has been processed via series of filter stages comprised of low and high pass filters, an undistorted and adequate PPG signal has attained at the output of easy pulse analyzer. The frequency, shape, and amplitude ingredients of the PPG signal dominantly rely upon the physiological states and age factor. Furthermore, the signal is then fed to Arduino processing board which forms the provision of interfacing among easy pulse electronic module and personal computer in order to have the Graphical User Interface (GUI). The outcomes are quite obvious and are indicative of the physical states in terms of short and long term variability. IEEE 2016 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/50910/4/50910.pdf application/pdf en http://irep.iium.edu.my/50910/5/50910-Poincare_based_PPG_signal_analysis_for_varying_physiological_SCOPUS.pdf Kazmi , Syed Absar and Shah, Mansoor Hussain and Khan, Sheroz and Khalifa, Othman Omran and ., Muhammad Muzammil (2016) Poincare based PPG signal analysis for varying physiological states. In: 2016 International Conference on Intelligent Systems Engineering (ICISE), Islamabad, Pakistan. http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=7475170 10.1109/INTELSE.2016.7475170
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic T10.5 Communication of technical information
spellingShingle T10.5 Communication of technical information
Kazmi , Syed Absar
Shah, Mansoor Hussain
Khan, Sheroz
Khalifa, Othman Omran
., Muhammad Muzammil
Poincare based PPG signal analysis for varying physiological states
description This paper investigates the similarity and dissimilarity of the Photoplethysmography (PPG) signals depending upon the physiological conditions in non­linear domain. Current paper also illustrates the variations in PPG signal for volunteers of age group among 20's (twenties). Easy Pulse analyzer Sensor module which operates on working principle of pulse oximetry which enables the photo sensing technique by detecting the infra­red light penetrating through the respective part of body in this case is index finger. Afterwards it has been processed via series of filter stages comprised of low and high pass filters, an undistorted and adequate PPG signal has attained at the output of easy pulse analyzer. The frequency, shape, and amplitude ingredients of the PPG signal dominantly rely upon the physiological states and age factor. Furthermore, the signal is then fed to Arduino processing board which forms the provision of interfacing among easy pulse electronic module and personal computer in order to have the Graphical User Interface (GUI). The outcomes are quite obvious and are indicative of the physical states in terms of short and long term variability.
format Conference or Workshop Item
author Kazmi , Syed Absar
Shah, Mansoor Hussain
Khan, Sheroz
Khalifa, Othman Omran
., Muhammad Muzammil
author_facet Kazmi , Syed Absar
Shah, Mansoor Hussain
Khan, Sheroz
Khalifa, Othman Omran
., Muhammad Muzammil
author_sort Kazmi , Syed Absar
title Poincare based PPG signal analysis for varying physiological states
title_short Poincare based PPG signal analysis for varying physiological states
title_full Poincare based PPG signal analysis for varying physiological states
title_fullStr Poincare based PPG signal analysis for varying physiological states
title_full_unstemmed Poincare based PPG signal analysis for varying physiological states
title_sort poincare based ppg signal analysis for varying physiological states
publisher IEEE
publishDate 2016
url http://irep.iium.edu.my/50910/
http://irep.iium.edu.my/50910/
http://irep.iium.edu.my/50910/
http://irep.iium.edu.my/50910/4/50910.pdf
http://irep.iium.edu.my/50910/5/50910-Poincare_based_PPG_signal_analysis_for_varying_physiological_SCOPUS.pdf
first_indexed 2023-09-18T21:12:02Z
last_indexed 2023-09-18T21:12:02Z
_version_ 1777411317272936448