Electro-goniometric system: an instrumentation to capture knee movements for forward walking

Continuous monitoring, accuracy of evaluation, and proper analysis of human gait characteristics have presented the importance not only in clinical studies, but also in the field of sports, rehabilitation, training, and robotics research. Human knee joint plays an important role in balancing and sta...

Full description

Bibliographic Details
Main Authors: Akhtaruzzaman, Md., Shafie, Amir Akramin, Khan, Md. Raisuddin
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2015
Subjects:
Online Access:http://irep.iium.edu.my/48394/
http://irep.iium.edu.my/48394/
http://irep.iium.edu.my/48394/
http://irep.iium.edu.my/48394/1/48394.pdf
http://irep.iium.edu.my/48394/4/ASCC-organizer.pdf
id iium-48394
recordtype eprints
spelling iium-483942016-07-18T13:13:33Z http://irep.iium.edu.my/48394/ Electro-goniometric system: an instrumentation to capture knee movements for forward walking Akhtaruzzaman, Md. Shafie, Amir Akramin Khan, Md. Raisuddin TJ210.2 Mechanical devices and figures. Automata. Ingenious mechanism. Robots (General) TJ212 Control engineering Continuous monitoring, accuracy of evaluation, and proper analysis of human gait characteristics have presented the importance not only in clinical studies, but also in the field of sports, rehabilitation, training, and robotics research. Human knee joint plays an important role in balancing and stabilizing human body while walking. So it is obvious to observe knee joint movement characteristics as a part of gait analysis. In this paper, instrumentation for capturing knee joint movement pattern is presented. The instrumentation is designed based on Electro-goniometric mechanism with flexible joints on arms that attached with upper and lower extremity of lower limbs. The electrical signals obtained from the instrumentation are calibrated carefully to present the movement angles in degree. The instrumentation system is viable to represent knee movement pattern of human walking which is compared with the result of image based analysis. IEEE 2015 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/48394/1/48394.pdf application/pdf en http://irep.iium.edu.my/48394/4/ASCC-organizer.pdf Akhtaruzzaman, Md. and Shafie, Amir Akramin and Khan, Md. Raisuddin (2015) Electro-goniometric system: an instrumentation to capture knee movements for forward walking. In: 2015 10th Asian Control Conference (ASCC 2015), 31st May- 3rd June 2015, Kota Kinabalu, Sabah. http://ieeexplore.ieee.org/xpl/articleDetails.jsp?reload=true&arnumber=7244519 10.1109/ASCC.2015.7244519
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic TJ210.2 Mechanical devices and figures. Automata. Ingenious mechanism. Robots (General)
TJ212 Control engineering
spellingShingle TJ210.2 Mechanical devices and figures. Automata. Ingenious mechanism. Robots (General)
TJ212 Control engineering
Akhtaruzzaman, Md.
Shafie, Amir Akramin
Khan, Md. Raisuddin
Electro-goniometric system: an instrumentation to capture knee movements for forward walking
description Continuous monitoring, accuracy of evaluation, and proper analysis of human gait characteristics have presented the importance not only in clinical studies, but also in the field of sports, rehabilitation, training, and robotics research. Human knee joint plays an important role in balancing and stabilizing human body while walking. So it is obvious to observe knee joint movement characteristics as a part of gait analysis. In this paper, instrumentation for capturing knee joint movement pattern is presented. The instrumentation is designed based on Electro-goniometric mechanism with flexible joints on arms that attached with upper and lower extremity of lower limbs. The electrical signals obtained from the instrumentation are calibrated carefully to present the movement angles in degree. The instrumentation system is viable to represent knee movement pattern of human walking which is compared with the result of image based analysis.
format Conference or Workshop Item
author Akhtaruzzaman, Md.
Shafie, Amir Akramin
Khan, Md. Raisuddin
author_facet Akhtaruzzaman, Md.
Shafie, Amir Akramin
Khan, Md. Raisuddin
author_sort Akhtaruzzaman, Md.
title Electro-goniometric system: an instrumentation to capture knee movements for forward walking
title_short Electro-goniometric system: an instrumentation to capture knee movements for forward walking
title_full Electro-goniometric system: an instrumentation to capture knee movements for forward walking
title_fullStr Electro-goniometric system: an instrumentation to capture knee movements for forward walking
title_full_unstemmed Electro-goniometric system: an instrumentation to capture knee movements for forward walking
title_sort electro-goniometric system: an instrumentation to capture knee movements for forward walking
publisher IEEE
publishDate 2015
url http://irep.iium.edu.my/48394/
http://irep.iium.edu.my/48394/
http://irep.iium.edu.my/48394/
http://irep.iium.edu.my/48394/1/48394.pdf
http://irep.iium.edu.my/48394/4/ASCC-organizer.pdf
first_indexed 2023-09-18T21:08:39Z
last_indexed 2023-09-18T21:08:39Z
_version_ 1777411104452902912