EMG based classification for continuous thumb angle and force prediction

Human hand functions range from precise-minute handling to heavy and robust movements. Remarkably, 50 percent of all hand functions are made possible by the thumb. Therefore, developing an artificial thumb which can mimic the actions of a real thumb precisely is a majo...

Full description

Bibliographic Details
Main Authors: Siddiqi, Abdul Rahman, Sidek, Shahrul Na'im, Roslan, Muhammad Rozaidi
Format: Conference or Workshop Item
Language:English
Published: IEEE 2015
Subjects:
Online Access:http://irep.iium.edu.my/47317/
http://irep.iium.edu.my/47317/
http://irep.iium.edu.my/47317/
http://irep.iium.edu.my/47317/4/47317.pdf
id iium-47317
recordtype eprints
spelling iium-473172019-01-10T05:01:09Z http://irep.iium.edu.my/47317/ EMG based classification for continuous thumb angle and force prediction Siddiqi, Abdul Rahman Sidek, Shahrul Na'im Roslan, Muhammad Rozaidi TA164 Bioengineering Human hand functions range from precise-minute handling to heavy and robust movements. Remarkably, 50 percent of all hand functions are made possible by the thumb. Therefore, developing an artificial thumb which can mimic the actions of a real thumb precisely is a major achievement. Despite many efforts dedicated to this area of research, control of artificial thumb movements in resemblance to our natural movement, still poses as a challenge. Most of the development in this area is based on discontinuous thumb position control, which makes it possible to recreate several of the most important functions of the thumb but does not result in totalimitation. This work looks into the classification of Electromyogram (EMG) signals from thumb muscles for the prediction of thumb angle and force during flexion motion. For this purpose, an experimental setup is developed to measure the thumb angle & force throughout the range of flexion and simultaneously gather the EMG signals. Further various different featuresare extracted from these signals for classification and the most suitable feature set is determined and applied to different classifiers. A ‘piecewise- discretization’ approach is used for continuous angle prediction. Breaking away from previous researches, the frequency-domain features performed better than the timedomain features, with the best feature combination turning out to be MDF-MNF-MNP. As for the classifiers, the Support Vector Machine proved to be the most accurate classifier giving about 70% accuracy for both angle and force classification and close to 50% for joint angle-force classification. IEEE 2015 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/47317/4/47317.pdf Siddiqi, Abdul Rahman and Sidek, Shahrul Na'im and Roslan, Muhammad Rozaidi (2015) EMG based classification for continuous thumb angle and force prediction. In: 2015 IEEE International Symposium on Robotics and Intelligent Sensors (IEEE IRIS20I5), 18th-20th October 2015, Langkawi, Kedah. http://ieeexplore.ieee.org/document/7451584/ 10.1109/IRIS.2015.7451584
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TA164 Bioengineering
spellingShingle TA164 Bioengineering
Siddiqi, Abdul Rahman
Sidek, Shahrul Na'im
Roslan, Muhammad Rozaidi
EMG based classification for continuous thumb angle and force prediction
description Human hand functions range from precise-minute handling to heavy and robust movements. Remarkably, 50 percent of all hand functions are made possible by the thumb. Therefore, developing an artificial thumb which can mimic the actions of a real thumb precisely is a major achievement. Despite many efforts dedicated to this area of research, control of artificial thumb movements in resemblance to our natural movement, still poses as a challenge. Most of the development in this area is based on discontinuous thumb position control, which makes it possible to recreate several of the most important functions of the thumb but does not result in totalimitation. This work looks into the classification of Electromyogram (EMG) signals from thumb muscles for the prediction of thumb angle and force during flexion motion. For this purpose, an experimental setup is developed to measure the thumb angle & force throughout the range of flexion and simultaneously gather the EMG signals. Further various different featuresare extracted from these signals for classification and the most suitable feature set is determined and applied to different classifiers. A ‘piecewise- discretization’ approach is used for continuous angle prediction. Breaking away from previous researches, the frequency-domain features performed better than the timedomain features, with the best feature combination turning out to be MDF-MNF-MNP. As for the classifiers, the Support Vector Machine proved to be the most accurate classifier giving about 70% accuracy for both angle and force classification and close to 50% for joint angle-force classification.
format Conference or Workshop Item
author Siddiqi, Abdul Rahman
Sidek, Shahrul Na'im
Roslan, Muhammad Rozaidi
author_facet Siddiqi, Abdul Rahman
Sidek, Shahrul Na'im
Roslan, Muhammad Rozaidi
author_sort Siddiqi, Abdul Rahman
title EMG based classification for continuous thumb angle and force prediction
title_short EMG based classification for continuous thumb angle and force prediction
title_full EMG based classification for continuous thumb angle and force prediction
title_fullStr EMG based classification for continuous thumb angle and force prediction
title_full_unstemmed EMG based classification for continuous thumb angle and force prediction
title_sort emg based classification for continuous thumb angle and force prediction
publisher IEEE
publishDate 2015
url http://irep.iium.edu.my/47317/
http://irep.iium.edu.my/47317/
http://irep.iium.edu.my/47317/
http://irep.iium.edu.my/47317/4/47317.pdf
first_indexed 2023-09-18T21:07:20Z
last_indexed 2023-09-18T21:07:20Z
_version_ 1777411021428752384