Inhalable and respirable dust from coal-fired power plant

Among the anthropogenic air pollutant that lead to the global warming, this research focuses on the inhalable dust and respirable dust that comes from the emissions of coal. Recently, the demand of electricity supply in Malaysiais raising and leads to the diversification of its resources towards the...

Full description

Bibliographic Details
Main Authors: Mohd Din, Shamzani Affendy, Othman, Rashidi, Nik Yahya, Nik Nurul Hidayah, Hanapi, Norsyamimi
Format: Article
Language:English
Published: Universiti Teknologi Malaysia 2015
Subjects:
Online Access:http://irep.iium.edu.my/47068/
http://irep.iium.edu.my/47068/1/6849-18744-1-SM.pdf
id iium-47068
recordtype eprints
spelling iium-470682016-07-19T02:07:45Z http://irep.iium.edu.my/47068/ Inhalable and respirable dust from coal-fired power plant Mohd Din, Shamzani Affendy Othman, Rashidi Nik Yahya, Nik Nurul Hidayah Hanapi, Norsyamimi RA Public aspects of medicine TA170 Environmental engineering Among the anthropogenic air pollutant that lead to the global warming, this research focuses on the inhalable dust and respirable dust that comes from the emissions of coal. Recently, the demand of electricity supply in Malaysiais raising and leads to the diversification of its resources towards the non-renewable energy. Coal-fired power plant emission had been recognized as one of the manmade sources of particulate matter. 8-hours personal particulate matter sampling had been done at a coal-fired power plant with 7-hole sampler at 2 L/min air flow and cyclone sampler at 2.2 L/min air flow. This study found that 96.78 % of the result from total inhalable dust exceeds the PM10DOE Malaysia standard of 0.15mg/m3. The percentage ratio of respirable towards total inhalable dust is 50.25%. Further analysis showed that as the temperature increases, the particulate matter concentration also increases. It is believed that the smaller particles offer higher degree of human health risk. The particulate from coal with aerodynamic diameter of 2.5 micron and lesser can be deposited into deeper part of lung and provide adverse health impact towards the public or residence of surrounding coal-fired power plant location area, generally and coal-fired power plant workers, in specific. Universiti Teknologi Malaysia 2015-12-21 Article PeerReviewed application/pdf en http://irep.iium.edu.my/47068/1/6849-18744-1-SM.pdf Mohd Din, Shamzani Affendy and Othman, Rashidi and Nik Yahya, Nik Nurul Hidayah and Hanapi, Norsyamimi (2015) Inhalable and respirable dust from coal-fired power plant. Jurnal Teknologi, 77 (30). pp. 1-6. ISSN 0127–9696 E-ISSN 2180–3722
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic RA Public aspects of medicine
TA170 Environmental engineering
spellingShingle RA Public aspects of medicine
TA170 Environmental engineering
Mohd Din, Shamzani Affendy
Othman, Rashidi
Nik Yahya, Nik Nurul Hidayah
Hanapi, Norsyamimi
Inhalable and respirable dust from coal-fired power plant
description Among the anthropogenic air pollutant that lead to the global warming, this research focuses on the inhalable dust and respirable dust that comes from the emissions of coal. Recently, the demand of electricity supply in Malaysiais raising and leads to the diversification of its resources towards the non-renewable energy. Coal-fired power plant emission had been recognized as one of the manmade sources of particulate matter. 8-hours personal particulate matter sampling had been done at a coal-fired power plant with 7-hole sampler at 2 L/min air flow and cyclone sampler at 2.2 L/min air flow. This study found that 96.78 % of the result from total inhalable dust exceeds the PM10DOE Malaysia standard of 0.15mg/m3. The percentage ratio of respirable towards total inhalable dust is 50.25%. Further analysis showed that as the temperature increases, the particulate matter concentration also increases. It is believed that the smaller particles offer higher degree of human health risk. The particulate from coal with aerodynamic diameter of 2.5 micron and lesser can be deposited into deeper part of lung and provide adverse health impact towards the public or residence of surrounding coal-fired power plant location area, generally and coal-fired power plant workers, in specific.
format Article
author Mohd Din, Shamzani Affendy
Othman, Rashidi
Nik Yahya, Nik Nurul Hidayah
Hanapi, Norsyamimi
author_facet Mohd Din, Shamzani Affendy
Othman, Rashidi
Nik Yahya, Nik Nurul Hidayah
Hanapi, Norsyamimi
author_sort Mohd Din, Shamzani Affendy
title Inhalable and respirable dust from coal-fired power plant
title_short Inhalable and respirable dust from coal-fired power plant
title_full Inhalable and respirable dust from coal-fired power plant
title_fullStr Inhalable and respirable dust from coal-fired power plant
title_full_unstemmed Inhalable and respirable dust from coal-fired power plant
title_sort inhalable and respirable dust from coal-fired power plant
publisher Universiti Teknologi Malaysia
publishDate 2015
url http://irep.iium.edu.my/47068/
http://irep.iium.edu.my/47068/1/6849-18744-1-SM.pdf
first_indexed 2023-09-18T21:06:59Z
last_indexed 2023-09-18T21:06:59Z
_version_ 1777410999110860800