Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement

We have developed a new ultrasound Doppler blood flow velocimeter which had a B-mode image system. A measurement of blood flow velocity was difficult under the movement, because a blood vessel was moved with muscle movement. But, this equipment is able to trace vessel position by using B-mode image....

Full description

Bibliographic Details
Main Authors: Yuji , HIRAO, Noor Azmi, Azran Azhim, Yohsuke , KINOUCHI
Format: Article
Language:English
Published: 2009
Subjects:
Online Access:http://irep.iium.edu.my/44092/
http://irep.iium.edu.my/44092/1/44092_-_Development_of_Blood_Flow_Velocimeter_of_Vessel_Position_Trace_Type_and_Measurement_of_Its_Velocity_in_the_Elbow_Flexor_and_Extensor_Movement.pdf
id iium-44092
recordtype eprints
spelling iium-440922016-04-06T02:41:14Z http://irep.iium.edu.my/44092/ Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement Yuji , HIRAO Noor Azmi, Azran Azhim Yohsuke , KINOUCHI TP248.13 Biotechnology We have developed a new ultrasound Doppler blood flow velocimeter which had a B-mode image system. A measurement of blood flow velocity was difficult under the movement, because a blood vessel was moved with muscle movement. But, this equipment is able to trace vessel position by using B-mode image. In this paper, attribute and schema of this equipment are explained. As an incidence angle of ultrasound beam changed under the movement, its correction was suggested. The result of application experiment, this equipment was useful for the measurement under the movement. 2009 Article PeerReviewed application/pdf en http://irep.iium.edu.my/44092/1/44092_-_Development_of_Blood_Flow_Velocimeter_of_Vessel_Position_Trace_Type_and_Measurement_of_Its_Velocity_in_the_Elbow_Flexor_and_Extensor_Movement.pdf Yuji , HIRAO and Noor Azmi, Azran Azhim and Yohsuke , KINOUCHI (2009) Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement. IEICE TRANSACTIONS on Information and Systems , J92-D (1). pp. 162-175. ISSN 1745-1361
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TP248.13 Biotechnology
spellingShingle TP248.13 Biotechnology
Yuji , HIRAO
Noor Azmi, Azran Azhim
Yohsuke , KINOUCHI
Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
description We have developed a new ultrasound Doppler blood flow velocimeter which had a B-mode image system. A measurement of blood flow velocity was difficult under the movement, because a blood vessel was moved with muscle movement. But, this equipment is able to trace vessel position by using B-mode image. In this paper, attribute and schema of this equipment are explained. As an incidence angle of ultrasound beam changed under the movement, its correction was suggested. The result of application experiment, this equipment was useful for the measurement under the movement.
format Article
author Yuji , HIRAO
Noor Azmi, Azran Azhim
Yohsuke , KINOUCHI
author_facet Yuji , HIRAO
Noor Azmi, Azran Azhim
Yohsuke , KINOUCHI
author_sort Yuji , HIRAO
title Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_short Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_full Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_fullStr Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_full_unstemmed Development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
title_sort development of blood flow velocimeter of vessel position trace type and measurement of its velocity in the elbow flexor and extensor movement
publishDate 2009
url http://irep.iium.edu.my/44092/
http://irep.iium.edu.my/44092/1/44092_-_Development_of_Blood_Flow_Velocimeter_of_Vessel_Position_Trace_Type_and_Measurement_of_Its_Velocity_in_the_Elbow_Flexor_and_Extensor_Movement.pdf
first_indexed 2023-09-18T21:02:43Z
last_indexed 2023-09-18T21:02:43Z
_version_ 1777410730812768256