A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations
We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems (FFDM) operate using Molybdenum/Molybdenum (Mo/Mo) and Tungsten/Rhodium (W/Rh) target/filter combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely N...
Main Authors: | , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
International Atomic Energy Agency
2013
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/41540/ http://irep.iium.edu.my/41540/ http://irep.iium.edu.my/41540/ http://irep.iium.edu.my/41540/1/45097313_IAEA_INIS.pdf |
id |
iium-41540 |
---|---|
recordtype |
eprints |
spelling |
iium-415402017-11-03T02:39:40Z http://irep.iium.edu.my/41540/ A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations Jamal, Noriah Abdul Hamid, Siti Selina Samad Cheung, Humairah Che Mohamed, Siti Kamariah Muhammed Nordin, Ellyda Hassan, Radhiana Dahalan, Rehir R Medicine (General) We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems (FFDM) operate using Molybdenum/Molybdenum (Mo/Mo) and Tungsten/Rhodium (W/Rh) target/filter combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely National Cancer Society and International Islamic University of Malaysia. The first centre operates using a W/Rh, while the second centre operates using an Mo/Mo target/filter combinations. On the basis of recorded information, data on mammographic views, MGD, age and Compressed Breast Thickness (CBT) were recorded for 100 patients, for each mammographic centre respectively. The MGD data were analyzed for variation with age group, with 5 years increment. The MGD data were also analyzed for variation with CBT, with 5 mm increment. We found that for both CC and MLO views, FFDM systems operated using Mo/Mo and W/Rh target/filter combinations present the same trend on MGD. The average MGD decreases as age increases. While average MGD increases with the increasing of CBT. However, FFDM system operates using Mo/Mo gives higher MGD as compared with FFDM system operates using W/Rh International Atomic Energy Agency 2013 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/41540/1/45097313_IAEA_INIS.pdf Jamal, Noriah and Abdul Hamid, Siti Selina and Samad Cheung, Humairah and Che Mohamed, Siti Kamariah and Muhammed Nordin, Ellyda and Hassan, Radhiana and Dahalan, Rehir (2013) A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations. In: Nuclear Technical Convention 2013, 8-10 Oct 2013, Bangi (Malaysia). http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/45/097/45097313.pdf 45097313 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
R Medicine (General) |
spellingShingle |
R Medicine (General) Jamal, Noriah Abdul Hamid, Siti Selina Samad Cheung, Humairah Che Mohamed, Siti Kamariah Muhammed Nordin, Ellyda Hassan, Radhiana Dahalan, Rehir A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations |
description |
We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems
(FFDM) operate using Molybdenum/Molybdenum (Mo/Mo) and Tungsten/Rhodium (W/Rh) target/filter
combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely
National Cancer Society and International Islamic University of Malaysia. The first centre operates using a W/Rh, while the second centre operates using an Mo/Mo target/filter combinations. On the basis of recorded information, data on mammographic views, MGD, age and Compressed Breast Thickness (CBT) were recorded for 100 patients, for each mammographic centre respectively. The MGD data were analyzed for variation with age group, with 5 years increment. The MGD data were also analyzed for variation with CBT, with 5 mm increment. We found that for both CC and MLO views, FFDM systems operated using Mo/Mo and W/Rh target/filter combinations present the
same trend on MGD. The average MGD decreases as age increases. While average MGD increases with the
increasing of CBT. However, FFDM system operates using Mo/Mo gives higher MGD as compared with FFDM
system operates using W/Rh |
format |
Conference or Workshop Item |
author |
Jamal, Noriah Abdul Hamid, Siti Selina Samad Cheung, Humairah Che Mohamed, Siti Kamariah Muhammed Nordin, Ellyda Hassan, Radhiana Dahalan, Rehir |
author_facet |
Jamal, Noriah Abdul Hamid, Siti Selina Samad Cheung, Humairah Che Mohamed, Siti Kamariah Muhammed Nordin, Ellyda Hassan, Radhiana Dahalan, Rehir |
author_sort |
Jamal, Noriah |
title |
A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations |
title_short |
A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations |
title_full |
A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations |
title_fullStr |
A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations |
title_full_unstemmed |
A survey on mean glandular dose from full-field digital mammography systems, operate using Mo/Mo and W/Rh target/filter combinations |
title_sort |
survey on mean glandular dose from full-field digital mammography systems, operate using mo/mo and w/rh target/filter combinations |
publisher |
International Atomic Energy Agency |
publishDate |
2013 |
url |
http://irep.iium.edu.my/41540/ http://irep.iium.edu.my/41540/ http://irep.iium.edu.my/41540/ http://irep.iium.edu.my/41540/1/45097313_IAEA_INIS.pdf |
first_indexed |
2023-09-18T20:59:28Z |
last_indexed |
2023-09-18T20:59:28Z |
_version_ |
1777410526686478336 |