Efficient method for the purification of coagulated sewage secondary effluent

Constant rate microfiltration experiments are conducted in purification of sewage secondary effluent pretreated with polyaluminum chloride (PAC). Monolithic ceramic membrane having a nominal pore size of 1.0 micro meter with 19 tubular channels is used as a filter medium. The system is capable of...

Full description

Bibliographic Details
Main Authors: Jami, Mohammed Saedi, Ohn, Than, Iritani, Eiji
Format: Conference or Workshop Item
Language:English
Published: 2010
Subjects:
Online Access:http://irep.iium.edu.my/23089/
http://irep.iium.edu.my/23089/1/p69.pdf
id iium-23089
recordtype eprints
spelling iium-230892012-04-09T00:28:53Z http://irep.iium.edu.my/23089/ Efficient method for the purification of coagulated sewage secondary effluent Jami, Mohammed Saedi Ohn, Than Iritani, Eiji TP Chemical technology Constant rate microfiltration experiments are conducted in purification of sewage secondary effluent pretreated with polyaluminum chloride (PAC). Monolithic ceramic membrane having a nominal pore size of 1.0 micro meter with 19 tubular channels is used as a filter medium. The system is capable of selecting the required mode of membrane cleaning, i.e., physical backwashing or chemically enhanced backwashing, based on the set value of the operating parameters. Flow resistance resulted from the formation of the filter cake is reduced by the physical backwashing, but in spite of this, the flow resistance increases gradually in a longer period of operation due to irreversible pore blocking. Hence chemically enhanced backwashing should be conducted occasionally. Sodium hypochlorite is used as cleaning agent and it is injected automatically when pore blocking reached to the preset level. The experimental results showed that the chemically enhanced backwashing is effective in restoring the increased portion of the flow resistance. The fully automatic system was found to be stable regardless of the variable influent quality and could be run at relatively higher flux of 3.0 m/d for a long period of time. The filtrate is free from pathogens and can be reused as reclaimed water for toilet flushing, car washing, etc. Furthermore, the results obtained under various operating conditions indicated that when process optimization is considered, there should be a trade off between the energy consumption and the amount of cleaning agent used per net filtrate volume. 2010 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/23089/1/p69.pdf Jami, Mohammed Saedi and Ohn, Than and Iritani, Eiji (2010) Efficient method for the purification of coagulated sewage secondary effluent. In: IIUM Research, Innovation & Invention Exhibition (IRIIE 2010), 26 - 27 January 2010, Kuala Lumpur.
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Jami, Mohammed Saedi
Ohn, Than
Iritani, Eiji
Efficient method for the purification of coagulated sewage secondary effluent
description Constant rate microfiltration experiments are conducted in purification of sewage secondary effluent pretreated with polyaluminum chloride (PAC). Monolithic ceramic membrane having a nominal pore size of 1.0 micro meter with 19 tubular channels is used as a filter medium. The system is capable of selecting the required mode of membrane cleaning, i.e., physical backwashing or chemically enhanced backwashing, based on the set value of the operating parameters. Flow resistance resulted from the formation of the filter cake is reduced by the physical backwashing, but in spite of this, the flow resistance increases gradually in a longer period of operation due to irreversible pore blocking. Hence chemically enhanced backwashing should be conducted occasionally. Sodium hypochlorite is used as cleaning agent and it is injected automatically when pore blocking reached to the preset level. The experimental results showed that the chemically enhanced backwashing is effective in restoring the increased portion of the flow resistance. The fully automatic system was found to be stable regardless of the variable influent quality and could be run at relatively higher flux of 3.0 m/d for a long period of time. The filtrate is free from pathogens and can be reused as reclaimed water for toilet flushing, car washing, etc. Furthermore, the results obtained under various operating conditions indicated that when process optimization is considered, there should be a trade off between the energy consumption and the amount of cleaning agent used per net filtrate volume.
format Conference or Workshop Item
author Jami, Mohammed Saedi
Ohn, Than
Iritani, Eiji
author_facet Jami, Mohammed Saedi
Ohn, Than
Iritani, Eiji
author_sort Jami, Mohammed Saedi
title Efficient method for the purification of coagulated sewage secondary effluent
title_short Efficient method for the purification of coagulated sewage secondary effluent
title_full Efficient method for the purification of coagulated sewage secondary effluent
title_fullStr Efficient method for the purification of coagulated sewage secondary effluent
title_full_unstemmed Efficient method for the purification of coagulated sewage secondary effluent
title_sort efficient method for the purification of coagulated sewage secondary effluent
publishDate 2010
url http://irep.iium.edu.my/23089/
http://irep.iium.edu.my/23089/1/p69.pdf
first_indexed 2023-09-18T20:35:00Z
last_indexed 2023-09-18T20:35:00Z
_version_ 1777408986395443200