Vibrational characteristics of piping system in air conditioning outdoor unit
The modal analysis of piping system in air conditioner (AC) outdoor unit is essential to investigate the vibration properties of the system. In view of the growing significance of numerical finite element (FE) model for vibration behaviour prediction, the AC piping elastic end support characterizati...
Main Authors: | Loh, S.K., Faris, Waleed Fekry, Chin, W. M. |
---|---|
Format: | Article |
Language: | English |
Published: |
Zhongguo Kexue Zazhishe
2011
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/11476/ http://irep.iium.edu.my/11476/ http://irep.iium.edu.my/11476/4/waleed_11ye1154.pdf |
Similar Items
-
Vibrational characteristics of piping system in air conditioning outdoor unit
by: Loh, S. K., et al.
Published: (2011) -
Fatigue analysis of Package Terminal Air Conditioner motor bracket under dynamic loading
by: Loh, S.K., et al.
Published: (2009) -
Three-dimensional vibration analysis of fluid-filled
pipes
by: Kolo, Isa, et al.
Published: (2013) -
Performance Of Solar Air-Conditioning System Using Heat
Pipe Evacuated Tube Collector
by: Moorthy, M.
Published: (2010) -
Random vibrations of a beam on elastic foundation
by: Faris, Waleed Fekry, et al.